Combustible Wall Clearance for Rear Vent Installation
If the stove is to be placed at side and back walls of combustible materials the following clearances
must be kept:
must be kept:
Refer to the manufacturer’s instructions concerning installation of listed single wall connector pipe,
wall thimble and chimney
wall thimble and chimney
Alcove Installation Requirements:
Whenever the stove is placed in a location where the ceiling height is less than 7’ tall, it is
considered an alcove installation. Because of the reduced height, the special requirements listed
below must be met.
considered an alcove installation. Because of the reduced height, the special requirements listed
below must be met.
Alcove installation
Connector pipe
A
B
C
D
E
F
USA Double
wall
60”
51”
22”
12”
10”
12.5”
Canada Double
wall
1520
1284
558
304
254
317
Rear outlet through wall
Connector pipe
A
B
D
USA Single
wall
11"
6"
21"
Canada Single
wall
280
152
533