Skylink WE-001 Fascicule

Page de 2
2. SETUP
 
    respectively to the existing wires from the wall : Load(Red) to load and 
    Live(Black) to live.
Secure the Wall Switch with the provided screws.
  The two blue LEDs will be on.
status of the load connected
Setup of the Wall Switch is simple. Simply replace your existing wall switch 
by the Wall Switch. 
CAUTION
Installation is required and enclosed instructions must be followed 
carefully to all steps and notes. If you are uncertain or uncomfortable 
performing this installation, please consult a qualified electrician.  
This manual should also be retained for future reference. 
1. Turn off power to the circuit that you plan on installing the Wall Switch 
    to at the circuit breaker. 
WARNING
Failure to turn off power at the circuit breaker can result in electrical 
shock causing severe or fatal injury.
Note: 
The Wall Switch is designed to operate maximum load of 1000W at 
120VAC.  
2. Follow the diagrams below to install the Wall Switch with the 2 wires: 
    Live, Load.  Use the provided  wire nuts to connect these wires 
3. After all the wires are connected, ensure that all of the wire connectors 
    are attached securely and there should be no exposed copper wiring. 
    
4. Turn the circuit breaker back on. 
5. The 
 will be off. The Wall Switch is now 
    installed and you can begin programming to learn transmitters into the 
    Wall Switch. 
3. PROGRAMMING TRANSMITTERS (TC SERIES)  / SENSORS (CONT)
3. PROGRAMMING TRANSMITTERS (TC SERIES) / SENSORS
There are 2 operating modes with the 
 :
1) Switch Mode - When a valid signal is received,  it will turn on or off the
    load
2) Countdown Timer Mode - When a valid signal is received, the load will 
    be on for a specific period of time,  1 minute, 5 minutes, 15 minutes, 
    30 minutes, or 60 minutes. This is mainly for  energy saving.
Wall Switch
In order to operate the 
remotely with a transmitter or sensor, it 
must be programmed to the 
.  Each module can be operated 
by up to 8 different transmitters (or 8  different command signals). 
Wall Switch 
Wall Switch
You can program multiple transmitters / sensors to the module and 
different transmitter / sensor can activate a different mode.
under Switch
Mode
Push the square 
    button on the Wall Switch. 
To program a TC series transmitter into the Wall Switch 
,  follow the instructions below: 
1. Wall Switch must be installed and powered properly. 
The connected load should be on, and the 
    2 blue LEDs are off.
2. Press and hold the “SET” button for about 3 seconds,  until the upper 
    blue LED flashes. 
3. You may now release the “SET” button. The blue LED will continue to 
    flash quickly for about 15 seconds. 
Operating Mode
Switch
Countdown Timer
Upper LED Indication
Flashes quickly
Steadily On
4. Within 15 seconds, follow steps A) to C).
     A. Press the PROG button on the back of the 
         TC transmitter.
     B. Press the button on the TC transmitter that 
          you would like to program into the module. 
     C. Once the transmitter is programmed, the 
          
 LED on the 
 flash 
          quickly then stop flashing, indicating you 
          have successfully programmed the trans-
          mitter to the module. Now the programmed 
          transmitter 
two blue LEDs
Wall Switch
button is ready to be used for 
          Switch Mode
To program a TC series transmitter into the Wall Switch under 
Countdown Timer Mode, follow the instructions below:
1. Wall Switch must be installed and powered properly. Push the square 
    button on the Wall Switch. The connected load should be on, and the 
    2 blue LEDs are off.
2. Press and hold the "SET" button for about 9 seconds, until the upper
    blue LED is steadily on.
3. You may now release the "SET" button. The blue LED will continue to 
    be on for about 15 seconds.
4. Within 15 seconds, follow steps A  to C.
     A. Press the PROG button on the back of the TC transmitter.
     B. Press the button on the TC transmitter that you would like to 
          program .
     C. Once the transmitter is programmed, the two blue LEDs on the  
          Wall Switch flash quickly then stop flashing, indicating you have 
          successfully programmed the transmitter to the module.  Now the 
          programmed transmitter button is ready to be used for Countdown 
          Timer Mode.
Note: To program other transmitters/sensors, please refer to the 
instructions of those transmitters/ sensors and the above instructions.
Note: You must complete the programming sequence within the 
15-second interval, otherwise, the Wall Switch will quit from programming 
mode and you need to start again from step 1 if the blue LED is off. 
1. INTRODUCTION
Wall Switch
WE-001 
Model WE-001
Wall Switch
Wire nuts
TM
Thank you for your purchase of a SkylinkHome  receiver, Wall Switch, 
Model WE-001.  Simply replace your existing wall switch with this Wall 
Switch, you can then wirelessly turn on and off 
TM
 with a SkylinkHome   transmitter. 
The Wall Switch WE-001 can communicate with up to 8 transmitters, so 
user has the option to add more transmitters to the system, such as more 
remote controls, or motion sensors etc. 
All wireless signal communications within the 
  System are 
based on rolling code technology to ensure highest security is used. 
The following items are included in this package:
- Wall Switch
- Wire nuts
-  
lights or appliances, 
etc
 
TM
SkylinkHome
User’s Instructions
Red
Load
Grey Antenna
Do not cut the antenna!
Black
Live
SET 
Button
Switch  Button
Blue 
LED
“PROG” button
Press the
desired 
button
4. SET TIMER DURATION
As mentioned, the timer can be set to the following durations, 1 minute, 
5 minutes, 15 minutes, 30 minutes, or 60 minutes. 
This timer duration is used for Countdown Timer Operating Mode. 
Note:
Antenna 
( grey wire) -- Do not cut it, keep it as straight as possible. 
Put the antenna directly  into the dry wall or through a hole of the 
metal box into the dry wall to get more control distance with a remote. 
TC-318-3
1. Wall Switch must be installed and powered properly. The connected 
    load should be off, and the 2 blue LEDs are on. The load must be off in 
    order to set the timer duration.
2. Press and hold the SET button for 3 seconds, the lower blue LED 
    flashes once. The number of flashes indicates the timer duration: