Alarms
Power Supplies and Alarms
If a Power Supply fails while the E1200i is operating, the software generates a major alarm and an SNMP 
trap, lights the major LED, and activates the audible alarm.
When a Power Supply fails, the software also records one alarm event for line cards, RPM, and SFM, 
though each contains its own power source. The system generates one alarm event and SNMP trap 
summarizing the Power Supply failure and the components affected.
Line Card
Hardware failure
major (red)
major
amber
no
Exceeds high temperature limit
major (red)
major
unlit
yes
Exceeds warning temperature 
limit
minor (amber)
minor
green
yes
Individual interface fails
minor (amber)
reported
amber
2
no
RPM (Non-redundant Configuration with 1 RPM)
Exceeds high temperature limit
major (red)
major
unlit
yes
Exceeds warning temperature 
limit
minor (amber)
minor
green
no
RPM fails but CP is ok
major (red)
major
amber
yes
SFMs (Redundant Configuration with 10 SFMs)
Exceeds high temperature limit
major (red)
major
unlit
yes
Exceeds warning temperature 
limit
minor (amber)
minor
green
no
Any card fails
minor (amber)
minor
amber
no
Any card removed
minor (amber)
minor
unlit
no
8 SFMs (Non-Redundant Configuration)
Exceeds high temperature limit
major (red)
major
unlit
yes
Exceeds warning temperature 
limit
minor (amber)
minor
green
no
Any card fails
major (red)
major
amber
yes
Any card removed
major (red)
major
unlit
yes
1 Event appears only in the show alarms command output.
2 The interface’s Link LED is unlit.
Table 14   Alarm Events and Reporting
Module
Alarm Event
Alarm LED 
Reported in 
event log
Status LED 
on Module
Audible 
Alarm?