Mocomtech CIM-550 Manuel D’Utilisation

Page de 460
CiM-550 IP Enabled Satellite Modem 
Rev. 2 
Serial Remote Control 
CD/CIM550.IOM 
56 
EIA 485 (full duplex) summary:  
 
Two differential pairs  - one pair for controller to target, one pair for target to 
controller. 
 
Controller-to-target pair has one line driver (controller), and all targets have line-
receivers. 
 
Target-to-controller pair has one line receiver (controller), and all targets have tri-
state drivers. 
5.3 EIA-232 
This a much simpler configuration in which the controller device is connected directly to 
the target via a two-wire-plus-ground connection. Controller-to-target data is carried, via 
EIA-232 electrical levels, on one conductor, and target-to-controller data is carried in the 
other direction on the other conductor. 
5.4 B
ASIC 
P
ROTOCOL
 
Whether in EIA-232 or EIA-485 mode, all data is transmitted as asynchronous serial 
characters, suitable for transmission and reception by a UART. In this case, the 
asynchronous character format is fixed at 8 data bits, one stop bit, no parity. The baud 
rate may vary between 50 baud and 19,200 baud.  
All data is transmitted in framed packets. The controller is assumed to be a PC or ASCII 
dumb terminal, which is in charge of the process of monitor and control. The controller is 
the only device which is permitted to initiate, at will, the transmission of data. Targets are 
only permitted to transmit when they have been specifically instructed to do so by the 
controller. 
All bytes within a packet are printable ASCII characters, less than ASCII code 127. In 
this context, the Carriage Return and Line Feed characters are considered printable. 
All messages from controller to target require a response (with one exception). This will 
be either to return data which has been requested by the controller, or to acknowledge 
reception of an instruction to change the configuration of the target. The exception to this 
is when the controller broadcasts a message (such as Set time/date) using Address 0, 
when the target is set to EIA-485 mode.