Fortress Technologies ALARM COMBO SYSTEM FS-50 Manuel D’Utilisation

Page de 32
 
25 
PROGRAMMABLE OPTIONS Cont. 
 
29. Aux #4 Time control: (1 sec. to 255 sec.) Default = 12 seconds
 
This option determines the length  of  time that is outputted from Aux #4  (Green/White  wire).   Pressing the Lock or 
Unlock buttons on the remote raises or lowers the time by one second. 
30. Turbo Timer Mode: 
The optional Turbo Timer mode allows the CoolStart system to keep a Turbo or Turbo Diesel vehicle running for 1 to 
5 minutes [selectively] after you remove the key and exit the vehicle.  This is handy for turbo cool-down without the 
need for expensive turbo timers.  This mode requires the use of an extra part called a momentary switch/button that 
is not included with the kit.  There are (3) modes of operation for the Turbo Timer Mode. See operation manual. 
31. Option Reset: RESTORE TO DEFAULT  
This option allows you to restore all programmable options to factory default values.  Go to the option 31 and press 
the Unlock Button #2 on the remote.  The lights flash 2 times and all values will be reset to factory original settings.  
Default values are marked with asterisks in the chart on pages 20 and 21. 
 
PROGRAMMABLE OPTION RESET 
 
 
This system provides a reset method to restore all options to FACTORY DEFAULT VALUES as listed in the “Button 
#2”  column  of  the  programmable  option  chart  on  pages  20-21.    This  can  be  helpful  if  you  have  lost  track  of  the 
option settings on your system, or when you are moving the system from car to car and want a “clean slate”. 
1.  Open hood (ground the Blue wire if no hood pin is installed) 
2.  Turn Key to the ON position (Pink ignition wire must be connected) 
3.  Press program / valet button 5 times, after a few seconds the unit will flash the lights 5 times. 
4.  Push the valet/program button 31 times.  Press carefully, do not lose count!  You must get a light flash each time 
you press the button.   If the unit didn’t flash the lights, then the system did not register your press. 
5.  Press button #2 (Unlock) to reset the options. (Lights should flash twice)
 
6.  Turn Ignition OFF, Close hood (un-ground Blue wire).  All features should be set at *DEFAULT values.