3. The following information is displayed:
SwapMembers of an SSA RAID Array
Type or select values in entry fields.
Press Enter AFTER making all desired changes.
[Entry Fields]
SSA RAID Manager
ssa0
SSA RAID Array
hdisk3
Connection Address / Array Name
09523173A02137K
* Disk To Remove
+
* Disk To Add
+
F1=HelpF2=Refresh
F3=Cancel
F4=List
F5=Reset
F6=Command
F7=Edit
F8=Image
F9=Shell
F10=Exit
Enter=Do
Select Disk to Remove, and press the List key.
4. From the displayed list, select the disk drive that you want to remove, and press
Enter.
Note: If the disk drive that you are replacing has been removed, or the array has
rejected it, it is listed as BlankReservedZ.
5. Select Disk to Add, and press the List key.
6. From the displayed list, select the name of the disk drive that you want to add, and
press Enter.
7. Press Enter to perform the swap operation.