Compex Systems SA33-3285-02 Manuel D’Utilisation

Page de 531
MAP 2320: SSA Link
This MAP helps you to isolate FRUs that are causing an SSA loop problem between a
device and the SSA adapter, or between two devices. If you are not familiar with SSA
loops, read the section Chapter 2, “Introducing SSA Loops” on page 7 before using this
MAP. Chapter 2, “Introducing SSA Loops” explains SSA links, strings, and loops.
Attention:
Unless the using system needs to be switched off for some other reason,
do not switch off the using system when servicing the SSA loop. Enclosure power
cables and external SSA cables that connect the devices to the using system can be
disconnected while that system is running.
1.
Are the system service aids available?
NO
Go to 2.
YES
Go to step 3.
2. (from step 1)
Are any Ready (link status) lights flashing on this SSA loop?
NO
YES
Go to “SSA Link Errors” on page 478 to analyze the problem.
3. (from step 1)
Run the Link Verification service aid (see “Link Verification Service Aid” on
page 383), 
and select the appropriate SSA adapter from the displayed Link
Verification adapter menu.
If the service aid detects pdisks for the adapter you have selected, a list of pdisks is
displayed. The diagram shows an example list:
LINK VERIFICATION
802386
SSA Link Verification for:
nunu:ssa0
00-04
IBM SSA 160 SerialRAID Adapter (
To Set or Reset Identify, move cursor onto selection, then press <Enter>.
Physical
Serial#
Adapter Port
A1 A2 B1 B2
Status
[TOP]
nunu:pdisk11
AC7AA09A
0
5
Good
nunu:pdisk8
AC7AA2D6
1
4
Good
nunu:pdisk2
AC7AA0BD
2
3
Good
nunu:pdisk3
AC7AA0B1
3
2
Good
nunu:pdisk7
AC7AA0B5
4
1
Good
nunu:pdisk12
AC7AA052
5
0
Good
nunu:pdisk0
AC7AA0B9
0
5
Good
nunu:pdisk1
AC7AA0B3
1
4
Good
nunu:pdisk10
AC7AA0B4
2
3
Good
[MORE...4]
F3=Cancel
F10=Exit
Chapter 18. SSA Problem Determination Procedures
445