Allstar Products Group Twist'R Plus Class I Vehicular Swing Gate Operator Manuel D’Utilisation

Page de 24
12 
CONNECTING THE OPERATOR TO THE 
ELECTRICAL SERVICE 
It will be necessary to run two conduits to the RS4000.   One will be 
used for the A-C power lines and another for the low voltage, class 2 
wiring. See Figure 8.   There are cutouts on the bottom of the 
Operator Chassis to accept these two conduits.  
 
The high voltage RS4000 electrical connections are made at the 
2
z
x
z
4 handy box located inside the operator at the rear, left corner 
along with the main power switch. Conduit should be run from the 
service breaker panel to this junction box as discussed in Section B, 
along with the appropriate AWG wire (see Table 1). The color code 
for 115 VAC is:  
black = hot                      white = neutral                       green = ground 
Connections for the 115 VAC service should be made according to 
the schematic wiring diagram, Figure 12, and handy box illustration 
shown in Figure 11.
 
Starting at the RS4000 2 x 4 handy box proceed as follows: 
1. The BLACK wire attaches to the 115 VAC HOT wire, normally 
black. 
2. The WHITE wire attaches to the 115 VAC NEUTRAL wire, 
normally white. 
3. The GREEN wire attaches to the GROUND wire, normally green. 
It is good electrical practice to ground the frame of the RS4000  
operator and is required by National and/or local electrical codes. 
 
TO AVOID ELECTRICAL DAMAGE TO THE 
OPERATOR DO NOT ALLOW TOTAL WIRE 
LENGTH  FROM THE SERVICE BREAKER PANEL 
TO THE TWIST’R OPERATOR TO EXCEED THE 
WIRE LENGTH GIVEN IN TABLE
Z
1, PAGE 8. 
              WARNING! 
RISK OF ELECTROCUTION. 
DO NOT BEGIN THE ELECTRICAL 
CONNECTION PROCEDURES UNTIL THE 
POWER IS TURNED OFF AT THE  
CIRCUIT BREAKER 
            WARNING! 
C:
 INSTALLING THE OPERATOR 
110454   REV  B 
Figure 12:  Schematic & Wiring Diagram 
Figure 11:  Handy Box Illustration 
106507