Chapter Two: Command Set 
 
23
Command 
Argument 
Description 
-l / --ldname <ldname> 
-m/--cachemode <cache mode> 
Cache Modes - ld 
    0 - None    1 - Read     
    2 - Write    3 - Read-Write 
 
 
 
rescan raid 
-n/--controllerno <controller number> 
 
Initiates rescanning of the storage 
bus connected to the controller. 
remove raid 
-t/--type {spare} 
-d / --diskname <diskname or slotindex> 
-l/ --ldname <ldname> (for dedicated spare) 
-n/--controllerno <controllerno> 
For example: remove -t spare -d 3 -n 0 raid 
    remove -t spare -l /dev/md0 -d /dev/sdb raid 
Removes a drive assigned as a 
spare disk or dedicated disk. 
add raid 
-t/--type {spare} 
-d / --diskname or slotindex or 
enclosurenumber:slotindex- 
l/--ldname <ldname>(for dedicated spare) 
-n/--controllerno <controllerno> 
For example: add -t spare -d 1:4 -n 0 raid 
Adds the given drive as a global or 
dedicated hot spare. 
upgrade raid 
-t/--type {controller} 
-n/--controllerno <controller number> 
-o /--code <code> 
-l/ --length <length> 
Upgrades the firmware for 
controller. 
upgrade raid 
-t/--type {pd} 
-d / --diskname <diskname or slotindex> 
-n/--controllerno <controller number> 
-o /--code <code> 
-l/ --length <length> 
Upgrades the firmware for a 
physical disk.