Installing the Switch
CAUTION
Procedures are for qualified service personnel only.
In this chapter
Selecting a Site
Switch units can be mounted in a standard 19-inch equipment rack or on a flat surface. Be sure to 
follow the guidelines below when choosing a location.
The site should:
be at the center of all the devices you want to link and near a power outlet. 
be able to maintain its temperature within -40 to 65 °C (-40 to 149°F) and its humidity 
within 10% to 90%, non-condensing
provide adequate space (approximately two inches) on all sides for proper air flow 
be accessible for installing, cabling and maintaining the devices 
allow the status LEDs to be clearly visible
Make sure twisted-pair cable is always routed away from power lines, fluorescent lighting 
fixtures and other sources of electrical interference, such as radios and transmitters.
Make sure that the unit is connected to a separate grounded power outlet that provides 100 to 
240 VAC, 50 to 60 Hz, is within 2 m (6.6 feet) of each device and is powered from an 
independent circuit breaker. As with any equipment, using a filter or surge suppressor is 
recommended.