Burnham Apex Series Brochure
8
PA
G
E
©2013 Burnham Commercial
•
P.O. Box 3939, Lancaster, PA 17604
Phone: 888.791.3790
•
Fax: 717.293.5803
•
www.burnhamcommercial.com
Form No. CCIL02081-4/13-
3
Mc
Printed in the U.S.A.
Model
A
B
C
D
E
F
G
H
APX500
44-7/8"
22-1/8"
29"
39-11/16"
29-3/8"
3/4"
1-1/2"
1-1/2"
APX625
50-1/4"
—
24"
38-7/8"
31-5/8"
1"
2"
2"
APX725
50-1/4"
—
24"
38-7/8"
31-5/8"
1"
2"
2"
APX800
54-9/10"
28-3/8"
34-1/4"
48-1/16"
33-3/16"
1"
2"
2"
Model
I
K
L
M
N
O
P
APX500
12-1/4"
5"
7-7/16"
35"
17-5/16"
14-29/32"
16-11/16"
APX625
12-1/4"
5"
7-1/2"
35"
17-1/4"
7-1/4"
16-11/16"
APX725
12-1/4"
5"
7-1/2"
35"
17-1/4"
7-1/4"
16-11/16"
APX800
12-1/4"
5"
7-1/2"
35"
17-1/4"
7-1/4"
16-11/16"
Apex Dimensions
MODEL
RATINGS
NET
RATING
(MBH)
THERMAL
EFFICIENCY
GAS
CONNECTION
WATER
CONTENT
(Gal.)
APPROX.
SHIPPING
WEIGHT
(Lbs.)
HEAT
TRFR.
AREA
(SQ. FT.)
INTAKE
& VENT
DIA.
SUPPLY &
RETURN
CONNECTIONS
MIN.
INPUT
(MBH)
MAX.
INPUT
(MBH)
GROSS
OUTPUT
(MBH)
APX500
100
500
475
413
95%
3/4" NPT
4.2
375
50.8
4"
1-1/2" NPT
APX625
125
625
593
516
95%
1" NPT
5.5
430
76.2
6"
2" NPT
APX725
145
725
688
598
95%
1" NPT
5.5
430
76.2
6"
2" NPT
APX800
160
800
760
661
95%
1" NPT
5.0
430
65.3
6"
2" NPT
Apex Specifications & Ratings
Low voltage
knockouts
(24V)
knockouts
(24V)
F
Gas valve
inlet
H
Supply
tapping
Condensate
trap drain
M
N
O
Line voltage knockouts (115V)
A
B
C
D
E
I
K
L
P
Access panel
Access panel
FRONT
Apex
SPECIFICATIONS & DIMENSIONS
Condensate Neutralizer
Header Sensor–1/2NPT required for
multiple burner systems
Header sensor, alternate immersion
(103104-01)
RJ45 Cable Splitter (103192-01)
80 psi relief valve (all models)
100 psi relief valve (all models)
Tekmar 265-3 boiler modulating control
CSD-1 Kit–Includes high and low gas pressure switches,
manual reset high limit, manual reset low water cutoff
and gas valve leak test equipment.
Burnham Commercial Universal Gateway–
LonWorks or BacNet/Metasys/Modbus Compatible
Optional Equipment
ASME stainless steel heat exchanger
Stainless steel mesh burner
Full modulation, 5:1 turndown
Variable speed combustion blower
Negative reduction gas valve
Supply & Return temperature sensors
Flue gas temperature sensor
Sealed control compartment
Negative pressure lower cabinet
Outdoor air temperature sensor
Standard Equipment
Front-mounted terminal switch
Low voltage terminal strip
Line voltage junction box
Polypropylene condensate trap
Pressure relief valve, 50 psi for 500
Pressure relief valve, 60 psi for 625, 725, 800
Rear flue outlet
Stacking boiler brackets
Built-in lifting handles
PVC Vent Kit:
30" CPVC
90° Elbow
(2) Vent-terminals with
rodent screens
ABC2.1™ (Apex Boiler Control):
Touch screen display
Built-in diagnostics
Slide out drawer
Multiple boiler lead-lag control
Domestic water priority
Warm weather shut down
4-20 mA inputs for external modulation
LEFT SIDE