Dacor RGC365 Manuel De Montage

Page de 16
8
Installation Instructions
Verifying Proper Operation
 WARNING
Make sure that power to the electrical outlet is turned 
off at the circuit breaker or fuse box and that the gas is 
turned off at the gas supply valve before proceeding.
Verify that the power supply meets the specifications on 
page 3 before proceeding.
The cooktop must be properly grounded at all times when 
electrical power is applied. 
Prior to operating the cooktop, read the accompanying use 
and care manual carefully.
Make sure all the cooktop burner controls are in the 
1. 
OFF position.
Connect the power cord to the electrical outlet.
2. 
Turn on power to the electrical outlet at the circuit 
3. 
breaker or fuse box.
Depress and turn one burner control knob at a time 
4. 
slowly counterclockwise to the 
HIGH position. Verify 
that the associated burner igniter sparks, then return 
the knob to the 
OFF position. Repeat for all of the 
remaining control knobs.
Turn on the gas supply valve.
5. 
Perform the following ignition test for all of the burners:
6. 
Press and turn the control knob 
slowly counter-
clockwise to the 
HIGH position. Only the selected 
burner will spark. It may take up to four seconds 
for the burner to ignite, at which time the igniter 
will stop sparking. If ignition does not occur within 
four seconds, turn off the knob, wait for at least two 
minutes to allow any gas to dissipate, then repeat 
the test.
Once the burner lights, the control knob can be 
rotated counterclockwise from 
HIGH to LOW to 
adjust the flame height progressively. On dual burn-
ers turn the control knob to the simmer setting and 
make sure the low level flame can be adjusted. 
When the unit is installed properly, the flame will 
be steady. It will also have a sharp, blue inner cone 
that will vary in length proportional to the burner 
size.
NOTE: If the cooktop does not operate properly, follow these troubleshooting steps:
Verify that power and gas are supplied to the cooktop.
Check to make sure that the power plug is connected to the electrical outlet and that power is turned on at the circuit 
breaker or fuse box.
Check to make sure that the burners are properly seated.
If the burner continues to spark after ignition without stopping, have a licensed electrician check the electrical outlet 
for proper grounding or reversed polarity.
Repeat the above burner ignition test.

If the appliance still does not work, do not attempt to repair the appliance yourself. Contact the Dacor Customer Service 
Team at (800) 793-0093.
LOW
position
HIGH
position
Area of
operation
Knob position
indicator
Burner normally
lights when knob 
reachs this
position
ON
LOW
position
HIGH
position
LOW
position
HIGH
position
Knob position
indicator
Area of
operation
Area of
operation
Burner normally
lights when knob 
reachs this
position
ON
Single Burner Control Knob
Dual Burner Control Knob