Mounting the hood body 
•  Before attaching the hood body, tighten the two screws Vr lo-
cated on the hood body mounting points. 
•  Hook the hood body onto the screws 12a.
•  Fully tighten support screws 12a.
• Adjust screws Vr to level the hood body. 
Note: The Hood body should be secured to wall studs. If neces-
sary, install a wood support behind the dry wall, flush mounted 
between 2 studs. This will provide the necessary structure and 
support for mounting. 
12a
Vr
Connections 
DUCTED VERSION AIR EXHAUST SYSTEM 
When installing the ducted version, connect the hood to the 
chimney using a rigid 6” duct. 
• Install the damper 10 ø 6”. 
•  Fix the duct in position using sufficient pipe clamps (not sup-
plied). 
10
DUCTLESS VERSION AIR OUTLET 
•  Push fit connection 15 onto the hood body outlet.
•  Insert the connection extension pieces laterally 14.1 in connec-
tion 15.
•  Make sure that the outlet of the extension pieces 14.1 is hori-
zontally and vertically aligned with the chimney outlets. If this 
is not the case, adjust the position by either reversing the con-
nection extension pieces 14.1 and then reassemble as described 
previously. 
•   Ensure that the activated charcoal filters have been inserted. 