Dacor RV30X Guide De Montage

Page de 12

Blower Installation
wARNINg:
Do not slide the CABP3 blower 
over or beyond the mounting 
stop on the blower mounting 
groove. To do so may prevent 
the vent sleeve from raising and/
or lowering due to interference 
between the blower and the vent 
drive arm assembly.
Connecting the Exhaust Duct
NOTE:
Use duct tape to seal the 
connection between the blower 
outlet and duct. Support the duct 
weight as necessary to ensure 
sealed joints.
For the side or bottom knockouts use the supplied 
transition  (P/N  26619).  For  the  rear  knockout 
attach a 3 1/4" x 10" duct.
Electrical Connection
wARNINgS:
1.  Ensure that the power supply 
is disconnected before 
proceeding.
2.  Verify that the power supply 
matches the ratings found on 
the appliance data plate before 
proceeding.
3.  The complete appliance must 
be properly grounded at all 
times when electrical power is 
applied.
4.  Do not ground the appliance 
with the neutral (white) house 
supply wire. A separate 
ground wire must be utilized.
5.  If aluminum house supply 
wiring is used, splice the 
appliance copper wires to the 
aluminum house wiring with 
special connectors designed 
and agency-certified for this 
purpose. Follow the connector 
manufacturer’s recommended 
procedure carefully. Improper 
connection can result in a fire 
hazard.
N1
L1
N2
L2
N2
Gnd
BLK
WHT
120VAC, 60Hz, 15A
Supply power from
dedicated circuit breaker
GRN
WHT
L2
BLK
BLK
WHT
Gnd
GRN
Gnd
GRN
GRN
WHT
BLK
RV
REMP3/16 OR CABP3
wiring of RV with REMP3/16 or CABP3
Installing the Raised Vent
Loosely attach the support legs to the left and 
right sides of the plenum using the hex nuts 
provided. Place the vent into the rear of the 
countertop cutout. Adjust the support leg height 
so that the end caps are gently resting on the 
counter, then tighten the hex nuts. Secure the 
support legs to the cabinet floor with the screws 
provided. 
For the cabinet blower application, place the 
adhesive-backed foam tape provided with the 
cabinet blower onto the left and right vertical 
blower flanges. Slide the blower outlet into the 
exhaust duct, while making sure that the lower 
blower flange slides into the blower mounting 
groove on the vent. Use duct tape to seal the 
connection between the blower outlet and the 
duct. Support the duct weight as necessary to 
ensure sealed joints.
For downdraft vents utilizing the remote blowers, 
locate the vent cover found in the RV carton. 
Attach the adhesive-backed foam tape provided 
with the blower to the left and right vertical 
blower cover flanges. Attach the vent cover to 
the large opening in the front of the vent. The 
vent is now ready to be ducted for a remote 
blower installation.
NOTE:
For both the cabinet and remote 
systems, the vent must be 
installed in a vertical orientation.  
Do not mount the vent on a slant 
or angle.
6.   Failure to complete electrical 
connections properly may 
result in a damaged or non-
functional system. Follow the 
wiring diagrams carefully to 
ensure a proper installation. 
Both vent systems require a properly grounded, 
120 VAC, 60 Hz., 15 Amp electrical service. 
Max. full line load is 8 amps. Always use a 
dedicated circuit. Do not use the same circuit 
that the cooktop is using.
Make all electrical connections between the vent 
and blowers, then connect power to the vent as 
per the wiring diagrams shown on Page 5. Use 
wire nuts provided and electrical tape to secure 
all wiring connections at the blowers.