Whirlpool WGE755C0BE Guide D’Installation Rapide

Page de 24
8
Style 2: Direct wire strain relief
Use Phillips screwdriver to remove screws and slide 
cord/conduit plate down and out.
Position cord/conduit plate as shown in the following 
illustration.
Replace cord/conduit plate and insert screws.
Assemble a UL listed conduit connector in the opening.
Feed the flexible conduit through the strain relief, allowing 
enough slack to easily attach wiring to the terminal block.
Tighten strain relief screw against the flexible conduit.
5. Replace back panel and screws on rear of range.
6. Complete installation following instructions for your type of 
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
A. Removable retaining nut
B. Strain relief
A
B
If your home has:
And you will be 
connecting to:
Go to Section:
4-wire receptacle
(NEMA type 14-50R)
A UL listed, 
250-volt 
minimum, 
40-amp, range 
power supply 
cord
4-wire connection: 
Power supply cord
4-wire direct
A fused 
disconnect or 
circuit breaker 
box
4-wire connection: 
Direct wire
3-wire receptacle
(NEMA type 10-50R)
A UL listed, 
250-volt 
minimum, 
40-amp, range 
power supply 
cord
3-wire connection: 
Power supply cord
3-wire direct
A fused 
disconnect or 
circuit breaker 
box
3-wire connection:
Direct wire
(12.7 cm)
5"
3"
(7.6 cm)
1"
(2.5 cm)