Summit BIM45 Manuel Du Propriétaire

Page de 30
 
Ice Maker Performance Mode Instructions (cont’d) 
 
Please read the following installation methods before using, and choose the correct drain mode for 
your situation. Set up your ice maker accordingly. 
 
Performance Mode  Instructions 
Suitable situation 
Operation instruction 
Direct drainage 
mode 
(Recommended 
mode)
 
Excess water 
will be drained off 
by the outlet water 
pipe on the back of 
the unit 
 
The height of drain hole 
in the room   
≤100 mm (3-15/16”) 
Ref.: Fig. A, Fig. B & Fig. C
 
Screw Nut and Switch 
Condition 
screw nut(front) (3) + seal washer(front) (4)
lock
 
screw nut(back) (7) + seal washer(back) (6)
 
open
 
screw nut for valve seal (11)
 
lock
 
screw nut for valve seal (12)
 
open
 
force water outlet switch (8)
 
OFF
 
1. 
Please be sure the screw nut and switch are in the
above condition;
 
2. 
Use a certain length drain pipe,connect one side to 
the direct water outlet pipe connection (13), the 
other to the drain hole. Please be sure the 
connection is tight to avoid water leakage.
 
Drain pump mode 
(Recommended 
mode)
 
Excess water 
will be forced to drain 
out by the pump on 
back of the unit. 
The height of drain 
hole in the room is 
between 
101 mm~1500 mm 
(3-15/16”~59”) 
Ref.: Fig. A, Fig. B & Fig. C
 
Screw Nut and Switch 
Condition 
screw nut(front) (3) + seal washer(front)(4)
lock
 
screw nut(back) (7) + seal washer(back) (6)
open
 
screw nut for valve seal (11)
 
open
 
screw nut for valve seal (12)
 
lock
 
force water outlet switch (8)
 
ON
 
1. 
Please be sure the screw nut and switch are in the
above condition; 
2. 
Use a certain length drain pipe, connect one side to
the force water outlet pipe connector (10), the other 
to the drain hole.
 
Please be sure the connection is 
tight to avoid water leakage. 
The lengthen of drainpipe is no more than 6000 mm
(236-4/16”) in order to prevent slops return.
 
 
INSTALLATION INSTRUCTIONS