Thermador CIT36XKBB Manuel De Montage

Page de 28
8
Electrical requirements
You can find the identification plate with the electrical 
specifications on the underside of the appliance. The 
junctionbox must be located within 3 feet of the cooktop 
connection. It should be easily accessible for service 
purposes.
Power supply
CIT 36 XKB Models...
40 Amp circuit breaker
240 Volt, 3 Wire, 60 Hz
208 Volt, 3 Wire, 60 Hz
All with 39" (1 m) flexible conduit (included)
Prepare Installation Space
Create the cut-out in the countertop according to the 
installation diagram. The angle of the cut surface to the 
countertop must be 90°.
The lateral cut-out edges must be flat in order to ensure 
that the retaining springs are well-positioned on the 
appliance. With multi-layered countertops, secure strips 
laterally in the cut-out if necessary.
After creating cut-out, remove shavings. Seal cut 
surfaces in a heat- and water-resistant manner.
Observe minimum distance between device underside 
and furniture parts of 
3
/
8
" (10 mm).
The worktop must be reinforced if it is less than 20 mm 
thick. Otherwise, it is not stable enough. The reinforced 
countertop must support at least 60 kg (weight of 
cooktop, cookware and food combined). Reinforcement 
material used must be resistant to heat and moisture.
 DSSUR[ PP
&RQQHFWLRQ
Å-´%R[
 PD[ PP )LWWLQJ&RQGXLW  PP
&RQGXLWDSSUR[IW aPP 
 PLQ PP
DLUFOHDUDQFH
PLQ
PP 
PLQ PP
‘ PP
[
ƒ
PLQ
PP 
PLQ PP 
PLQ
PP 


PP


PP