Cleaning before use 
After you remove all of the packaging materials, clean the inside of your ice maker before 
using it. See the "Interior cleaning" in the Cleaning and Maintenance section.
 
 
Location requirements 
 
INSTALLATION CLEARANCES: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
• 
This ice maker should be properly installed by qualified personnel. 
• 
To ensure proper ventilation for your ice maker, the front  of the unit must be 
completely unobstructed. 
• 
When installing the ice maker under a counter, follow the recommended spacing 
dimensions shown. Allow approximately 2" (50 mm) of clearance at rear, 1/16” (2 mm) 
at the top and  1"  (25  mm)  at sides for proper air circulation. The installation should 
allow the ice maker to be pulled forward for servicing if necessary. 
• 
Choose a well ventilated area with room  temperatures  within the normal range.  This 
unit MUST be installed in an area protected from the elements, such as wind,  rain, 
water spray or drips. 
• 
The unit
 
should not be located next to ovens, grills or other high heat sources. 
• 
Installation of the ice maker requires a cold water supply inlet of ¼-in. (6.35mm) soft 
copper tubing with a shut-off valve. 
• 
The ice maker requires a continuous water supply with a minimum pressure of 15 psig 
and a static pressure not to exceed 80 psig. The temperature of the water feeding into 
the ice maker should be between 41°F (5°C) and 90°F (32°C) for proper operation. 
 
 
 
SIDE VIEW 
TOP VIEW 
Top of unit 
Front of unit 
Side        Side 
2” 
1” 
1” 
Rear of unit 
1/16”