Gas Dryer Grounding
IMPORTANT: The dryer must be electrically grounded in 
accordance with local codes and ordinances or, in the absence 
of local codes, with the National Electrical Code, ANSI/NFPA 70, 
latest edition, or Canadian Electrical Code, CSA C22.1. If codes 
permit and a separate ground wire is used, it is recommended that 
a qualified electrical installer determine that the ground path is 
adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association 
One Batterymarch Park, Quincy, MA 02269
CSA International 
8501 East Pleasant Valley Road 
Cleveland, Ohio 44131-5575
 
Do not ground to a gas pipe.
 
Do not have a fuse in the neutral or ground circuit.
 
 A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical 
circuit is required. A time-delay fuse or circuit breaker is also 
recommended. It is recommended that a separate circuit 
serving only this dryer be provided.
 
This dryer is equipped with a power supply cord having a 
3-prong grounding plug.
 
 To minimize the possibility of shock, the cord must be plugged 
into a mating, 3 prong, grounding-type outlet, grounded in 
accordance with local codes and ordinances. If a mating outlet 
is not available, it is the personal responsibility and obligation of 
the customer to have the properly grounded outlet installed by 
a qualified electrician.
 
 If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
 
 Check with a qualified electrician if you are not sure the dryer is 
properly grounded.
GAS DRYER INSTALLATION REQUIREMENTS
Electrical Requirements