Electrolux EW30GC55P Guide De Montage
High standards of quality at Electrolux Home Products, Inc.
mean we are constantly working to improve our products.
We reserve the right to change specifications or
discontinue models without notice.
Electrolux Cooktops /
E30_36DD75ESS Downdraft Vents
Countertop Preparation
2
9
/
16
"
Electrolux Major Appliances, N.A.
USA
•
10200 David Taylor Drive
•
Charlotte, NC 28262
•
1-877-4electrolux (1-877-435-3287)
•
electroluxappliances.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
electroluxappliances.ca
DIC_DDV_PREP EL 03/14
© 2014 Electrolux Home Products, Inc.
Cooktop/Downdraft Vent
Countertop Preparation Specifications
•
For detailed Cooktop installation, refer to model-specific product page and
installation guide on web. Plan installation so that all required minimum
clearances between cooktop, overhead cabinets and adjacent vertical walls
are provided.
•
Position cooktop/vent cutout so all required minimum clearances are met.
•
Minimum flat countertop area must meet or exceed combined overall width
and depth as shown. Standard 25" countertop depth may NOT be adequate
for some cooktop/vent installations, especially with backsplash.
•
Separate circuits required for cooktop and vent. (Refer to product-specific
electrical specifications.)
•
Always consult local and national electric and gas codes. Check local
building codes for installation requirements, as they may vary per locale.
Downdraft Vent Specifications
•
For detailed Downdraft Vent installations, refer to model-specific product
page and installation guide on web.
•
Voltage Rating –120V/ 60Hz/15 Amps
•
Connected Load (kW Rating) @120 Volts = 1.0kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for safe
operation.)
•
Amps @120 Volts = 8.0 Amps
•
Vent unit outside of building only.
•
Vent must be installed in vertical orientation only.
•
1,600 CFM remote exhaust blower (PN#5304444802) included with
vent – shipped in separate box.
•
Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.
•
When multiple elbows are necessary, ensure a minimum of 24" of straight
duct between any two elbows.
•
Thermal breaks such as short section of nonmetallic duct, should be used
in areas of extreme cold.
•
For most efficient airflow exhaust, use a straight run or as few elbows as
possible.
•
Cold weather installations should have additional backdraft damper
installed.
•
Installing a Downdraft Vent in combination with any gas cooking surface
will affect optimum burner efficiency.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
CooktoP/DowNDrAft VENt
CoUNtErtoP PrEPArAtioN
CoUNtErtoP PrEPArAtioN