Countertop Preparation Specifications
• 
For detailed Cooktop installation, refer to model-specific product page and 
installation guide on web. Plan installation so that all required minimum 
clearances between cooktop, overhead cabinets and adjacent vertical walls 
are provided.
• 
Position cooktop/vent cutout so all required minimum clearances are met.
• 
Minimum flat countertop area must meet or exceed combined overall width 
and depth as shown. Standard 25" countertop depth may NOT be adequate 
for some cooktop/vent installations, especially with backsplash.
• 
Separate circuits required for cooktop and vent. (Refer to product-specific 
electrical specifications.)
• 
Always consult local and national electric and gas codes. Check local 
building codes for installation requirements, as they may vary per locale.
Downdraft Vent Specifications
• 
For detailed Downdraft Vent installations, refer to model-specific product 
page and installation guide on web.
• 
Voltage Rating –120V/ 60Hz/15 Amps
• 
Connected Load (kW Rating) @120 Volts = 1.0kW  
(For use on adequately wired 120V, dedicated circuit having 2-wire 
service with a separate ground wire. Appliance must be grounded for safe 
operation.)
• 
Amps @120 Volts = 8.0 Amps
• 
Vent unit outside of building only.
• 
Vent must be installed in vertical orientation only.
• 
1,600 CFM remote exhaust blower (PN#5304444802) included with  
vent – shipped in separate box.
• 
Do not use flexible duct. Round duct instead of rectangular duct 
recommended, especially when elbows are required.
• 
When multiple elbows are necessary, ensure a minimum of 24" of straight 
duct between any two elbows.
• 
Thermal breaks such as short section of nonmetallic duct, should be used  
in areas of extreme cold.
• 
For most efficient airflow exhaust, use a straight run or as few elbows as 
possible.
• 
Cold weather installations should have additional backdraft damper 
installed.
• 
Installing a Downdraft Vent in combination with any gas cooking surface  
will affect optimum burner efficiency.
Note:  For planning purposes only. Refer to Product Installation Guide  
on the web at electroluxappliances.com for detailed instructions.
CooktoP/DowNDrAft VENt