Electrical
Installation must be electrically grounded in accordance 
with local codes or, in the absence of local codes, with the 
National Electrical Code, ANSI/NFPA 70. Refer to the illus-
trations below.
The electrical supply for the convection steam oven must 
be placed in an adjacent cabinet within reach of the 6'
 
(1.8 m)
 power cord. Locate the electrical supply as shown in 
the illustrations on pages 6–7. A separate circuit, servicing 
only this appliance is required. A ground fault circuit inter-
rupter (GFCI) is not recommended and may cause interrup-
tion of operation.
Performance may be compromised if the electrical supply is 
less than 240 volts.
ELECTRICAL REQUIREMENTS
Electrical Supply
grounded, 240/208 VAC, 60 Hz
Service
20 amp dedicated circuit
Receptacle
NEMA 6-20R grounding-type
Power Cord
6'
 (1.8 m)
 WARNING
ELECTRICAL SHOCK HAZARD: Plug into a grounded 
3-prong outlet. Do not remove ground prong. Do not 
use an adapter. Failure to follow these instructions can 
result in electric shock, fire or death.
NEMA
PLUG
GROUNDED
NEMA RECEPTACLE
3"
(76)
NEMA
PLUG
MINIMUM CORD
CLEARANCE
 
NEMA 6-20R receptacle.
 
Power cord clearance.
SPECIFICATIONS
 
Rating plate location.
 
RATING PLATE