COYOTE CSLX36NG Manuel

Page de 39
 
 
 
6 
the valves and damage the ignition system to where it will need full replacement.   
• 
Ventilation and the variable of your most common wind direction must always be considered when 
planning your outdoor cooking island. Just the same as you would plan the layout and measure your 
indoor  kitchen,  you  must  also  do  the  same  for  the  outdoors  but  you  can  not  forget  about  Mother 
Nature and the effects she can have on your outdoor cooking equipment.   
o
  Coyote Wind Guards: If you do run into a situation where you will have wind coming into 
the  back  of  the  unit,  Coyote  does  sell  "Wind  Guards"  that  help  keep  your  grilll  from 
overheating due to no exhaust occuring out the back of the grill. Our Wind Guards should 
never be  considered as a  guaranteed  solution to this problem.  They  are  only  intended  to 
help the wind divert up and over the top of the grill. If the wind is strong, then you can still 
have problems with the heat being trapped in the hood. Our Wind Guards can be purchased 
through any of our authorized dealers. 
Clearance
• 
TO NON-COMBUSTIBLE CONSTRUCTION: For non-combustible material, Coyote grills can 
be placed directly on, or adjacent to the non-combustible material. The hood on a Coyote grill 
pivots  mainly  on  the  body.  If  you  have  a  wall  or  partition  behind  the  unit  that  would  block 
ventilation, then a minimum of 7" clearance from the back of the grill to the wall is needed for 
the purpose of ventilation. If you do not have a wall or partition blocking the ventilation of the 
unit, then you only need an extra 2" behind the unit for the hood to open fully. If you wish to use 
the rotisserie option, you will want to make sure that you leave adequate space (at least 6") on 
each side of the grill so that the motor and rotisserie spit handle will have room on the counter, 
as these extend past the overall dimensions of the grill body. 
• 
CLEARANCE TO COMBUSTIBLE CONSTRUCTION: For combustible construction, you must 
have at least 24" clearance to any combustible material (in any direction) for a Coyote Warranty 
to  be  upheld  and  for  the  safety  of  the  homeowner.  You  can  NOT  locate  the  grill  under  any 
combustible material without an approved ventilation system directly located above the unit. 
• 
INSULATED  JACKETS  AND  COMBUSTIBLE  CONSTRUCTION: 
If  you  must  use  combustible 
material  to  build  your  grill  island  AND  you  are  going  to  be  within  24"  of  the  grill  with  this 
combustible  material,  then  you  must  use  the  appropriate  Coyote  Insulated  Jacket.  The 
insulated  jacket  will  act  as  a  barrier  to  protect  your  grill  island from  the  heat  and fire  of  your 
Coyote grill. If an insulated jacket is not used in a combustible material island, the warranty on 
the Coyote grill will be voided immediately and safety can not be ensured. 
For Built-in Installations 
A  built-in  grill  is  designed  for  easy  installation  into  masonry  enclosures.  For  non-combustible 
applications, the grill drops into the opening (as shown in cut-out detail drawing - Fig. A) and hangs 
from the grill body  itself. A bottom deck is not required  to support the grill from the bottom. It is also 
required that: 
• 
Two ventilation holes, of at least 20 sq inches in size, must be present to help release any gas 
from a leak. 
  As Propane is heavier than air, locate your vents at the tank valve height or lower 
• 
The counter should be flat and level in reference to the floor.   
LP TANK STORAGE MUST BE ISOLATED IN A SEPARATE COMPARTMENT FROM THAT OF THE 
GRILL AND IT MUST BE VENTED AS WELL. (RECOMMEND BOTTOM VENTS FOR LP)