All pipe sealants must be an approved type and resistant to the actions of LP gas. Never use 
pipe sealant on flare fittings. 
• 
The  installation  of  this  appliance  must  conform  with  local  codes  or,  in  the  absence  of  local 
codes, with either National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Natural Gas and Propane 
Installation  Code,  CSA  B149.1,  or  Propane  Storage  and  Handling  Code,  B149.2,  or  the 
Standard for Recreational Vehicles, ANSI A 119.2/ NFPA 1192M, and CSA Z240 RV Series, 
Recreational Vehicle Code, as applicable.                   
WARNING: 
Gas  valves  are  preset  at  the  factory  to  operate  on  LP  or  natural  gas.  If  you  wish  to 
convert, be sure to contact your grill dealer FIRST! 
 
 
This  propane  gas  grill  is  designed  to  operate  on  propane  gas ONLY,  at  a  pressure regulated  at  11” 
(279.4mm) water column (W.C.) when equipped with the correct propane orifices on the valves and a 
propane regulator on the supply line regulated at the residential meter. The LP gas grill is designed to 
be used with a standard 20 lbs gas cylinder and must be constructed and marked in accordance with 
specifications of the US Department of Transportation for propane gas cylinders.   
Always keep cylinder securely fastened in an upright position. Never connect an unregulated propane 
gas cylinder to the grill. 
Do not subject propane cylinders to excessive heat. 
CAUTION: 
Never  store  a  LP  gas  cylinder  inside  a  building  or  in  the  vicinity  of  any  gas-burning 
appliance. 
 
 
Cylinder Specifications 
Any L.P. gas supply cylinder used with this grill must be approximately 12 inches diameter and 18 
inches high. The maximum fuel capacity is 80% and is approximately 
20 pounds of propane. 
The L.P. cylinder must have a shut-off valve (see picture) terminating 
in a Type 1 L.P.   
A  Type  1  compatible  cylinder  with  a  Type  1  cylinder  valve  has  a 
back-check valve which does not permit gas flow, until a positive seal 
has been obtained. 
The  cylinder  must  be  arranged  for  vapor  withdrawal.  It  must  also 
include  a  collar  to  protect  the  cylinder  valve.  A  safety  relief  device 
having direct communication with the vapor space of cylinder must be 
provided. This will expel high pressure gas if the cylinder is overfilled 
or overheated which could result in fire or explosion. 
All L.P. gas cylinders used with this appliance shall be constructed and marked in accordance with 
the  specifications for  L.P.  gas cylinders  of  the U.  S.  Department  of Transportation (DOT)  or  the 
National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes for Transportation 
of Dangerous Goods; and Commission, as applicable; and shall be provided with a listed overfilling 
LP Gas Hook-up