Setting the Temperature Control 
•  You can set the temperature by touching the UP and DOWN symbols. When you first push 
either of the two buttons, the LED readout will show the temperature set previously. (The 
temperature preset at the factory is 38°F (3°C). 
•  The temperature you are setting will increase by one degree each time you touch the UP 
symbol, and will decrease by one degree each time you touch the DOWN symbol. 
•  The range of the temperature control is from 36°F to 43°F. 
•  To view the set temperature at any time, touch the UP or DOWN symbol. The set temperature 
will flash in the display window for 5 seconds. After 5 seconds, the temperature inside the unit 
will reappear in the display window. 
 
 
 
 
 
 
 
 
 
 
 
INTERIOR LIGHT 
The interior light makes it easy to view your wine labels and enhances the display of your collection. 
Touching the LIGHT key toggles between 2 modes of operation for the internal lights: functional (default) 
mode and showcase mode. If you are in functional (default) mode, the lights will turn on only when the 
door is open. If you are in showcase mode, the lights will be on whether or not the door is open. 
 
SABBATH MODE 
Sabbath mode is available for the observance of certain religious holidays. This mode turns off the 
displays, interior light and audible alarms and prevents them from turning on again. Normal cooling 
operations will still take place. 
 
To initiate Sabbath mode, press the POWER and LIGHT keys at the same time for at least 5 seconds. 
The indicator light will flash four times to confirm that Sabbath mode is ON.  Sabbath mode can be exited 
by repeating the above process. The Sabbath mode will automatically turn off after 96 hours. 
 
TEMPERATURE MEMORY FUNCTION 
In the event of a power interruption
 (power surge, breaker switch, etc.)
, the unit will remember the 
previous temperature settings, and when power is recovered, the cabinet temperature will return to the 
same set temperature as before the power supply was cut off.
 
 
TEMPERATURE ALARM / DOOR ALARM 
 
•  An audible alarm sounds if the storage temperature is not cold enough. The temperature display 
flashes at the same time. 
•  The cause of the temperature being too high may be: 
-  Warm items were placed inside 
-  Too much warm ambient air flowed in when the contents were being rearranged or removed 
-  Power failure for some time 
-  The appliance is faulty. 
NOTE: 
•  If the unit is unplugged, or power is lost or turned off, you must wait 3 to 5 minutes before 
restarting the unit. If you attempt to restart before this time delay, the unit will not start. 
•  When you use the unit for the first time or restart the unit after it has been shut off for a long 
time, there could be a few degrees variance between the temperature you select and the one 
indicated on the LED readout.  This is normal and is due to the length of the activation time. 
There should not be a problem once the unit has been running for a few hours.