Kenyon B80105 Manuel Du Propriétaire
For future reference, please record the serial number of your
cooktop here:
STEP #2
Check the Electrical Supply Requirements
This product must be installed in accordance with national, state and local electric codes. The
following table provides the correct voltage, amperage and frequency that must be supplied to the
cooktop.
The supply must be from an individual grounded circuit that is protected by a circuit breaker and
rated per the specifications for the various models as shown in the table above.
Max Connected
Required Power
Minimum
Kenyon Part # Model #
Load
Supply Input
Wire Size
B80101
IND2BLG
3700 Watts
240VAC/16A/50/60Hz
#12 AWG
B80105
IND2BLG
3700 Watts
240VAC/16A/50/60Hz
#12 AWG
B80201
IND2BLG
3700 Watts
240VAC/16A/50/60Hz
#12 AWG
B80205
IND2BLG
3700 Watts
240VAC/16A/50/60Hz
#12 AWG
Warning: If the electric power supply does not meet the product
specifications, consult with a licensed electrician before proceeding
with installation.
STEP #3
Countertop Preparation
Please read this section prior to making cutout for cooktop.
It is important to plan ahead for installation of the cooktop, keeping the following dimensions in
mind (please refer to Figure A).
5
Ensure you have the correct model for your countertop. Landscape models are designed for use
in standard 24” depth countertops. Portrait models are designed for use in islands and
applications with non-standard depth countertops. Generally 25 1/2” minimum countertop depth
is needed to install portrait models.