Perlick HP24RS34R Utilisation Et Entretien

Page de 12
11
perlick.com
perlick residential installation manual
Problem
Cause
Solution
Compartments are warmer than usual
Control preset is set to warm
•  Lower the setpoint temperature. Refer 
to changing the set point for the specific 
model
Light is staying on
•  Turn the manual light switch off.
Condenser is dirty or obstructed
•  Clean the condenser and clear 
obstruction.
The door is open or has been opened more 
frequently lately.
•  Wait 24 hours and recheck the 
temperature.
Internal louvers and/or the fan guard is 
obstructed.
•  Reset the preset temperature if necessary 
– refer to page 5 and 6 of this guide.
•  Make sure the louvers and/or the fan are 
not obstructed.
Warm product product was recently placed in 
the cabinet.
•  Wait 24 hours for product to chill, then 
recheck the temperature.
System runs for a long period of time.
Condenser is dirty or obstructed.
•  Clean the condenser and clear the 
obstruction.
Door was kept open for a long time or was 
opened more frequently, or warm product 
was recently placed in the cabinet.
•  Wait 24 hours and recheck temperature.
Hot day and warm room temperature
•  Normal for the system to run more 
frequently.
Condensation forms inside the compartments High humidity and/or frequent door opening
•  Normal operation
Door is not closing and sealing properly
•  Make sure the door is closing properly. 
Check the door seal and replace if 
necessary.
•  If condensation persists, contact Perlick 
Technical Service at 800-558-5592