1. CHECKING FUEL AND PROPER ORIFICES
Fire Magic units are equipped with orifi ces for
natural gas, unless otherwise indicated. For
use with propane gas, smaller orifi ces must
be installed to avoid hazardous overheating.
Please refer to Table 1 for the correct orifi ce
size. Check the orifi ce size by following the
instructions below. The drill size is stamped on
the orifi ce. If the number is not visible you may
have to remove the orifi ce (as detailed below)
to read the number stamped on the side of the
orifi ce.
natural gas, unless otherwise indicated. For
use with propane gas, smaller orifi ces must
be installed to avoid hazardous overheating.
Please refer to Table 1 for the correct orifi ce
size. Check the orifi ce size by following the
instructions below. The drill size is stamped on
the orifi ce. If the number is not visible you may
have to remove the orifi ce (as detailed below)
to read the number stamped on the side of the
orifi ce.
IF YOU ARE NOT SURE YOU HAVE THE
CORRECT SIDEBURNER ORIFICE SIZE (OR
WISH TO CHANGE THE ORIFICE), FOLLOW THE
STEPS BELOW.
CORRECT SIDEBURNER ORIFICE SIZE (OR
WISH TO CHANGE THE ORIFICE), FOLLOW THE
STEPS BELOW.
CAUTION: IF THE BURNER HAS BEEN IN USE,
WAIT UNTIL THE BURNER AND ITS
COMPONENTS ARE COOL TO THE
TOUCH.
COMPONENTS ARE COOL TO THE
TOUCH.
a. Remove sideburner lid and lift off cooking
grid.
b. Remove the control knob and screws fi rst,
then carefully lift away the control panel.
Important: Prior to fully removing the
c o n t r o l p a n e l , yo u mu s t
disconnect the battery holder
assembly wires that are
located behind the control
panel.
disconnect the battery holder
assembly wires that are
located behind the control
panel.
c. Reach up under the burner support and
remove the burner retaining clip (see Fig.
5-1), located at the rear of the burner pipe.
5-1), located at the rear of the burner pipe.
d. Remove the burner top and carefully lift
burner up and out, clearing the ceramic
electrode (see Fig. 5-2), and pulling the
burner tube away from the orifi ce, located on
the end of the valve on the manifold at the
front of the unit (see Fig. 5-3).
electrode (see Fig. 5-2), and pulling the
burner tube away from the orifi ce, located on
the end of the valve on the manifold at the
front of the unit (see Fig. 5-3).
Note: You do not have to lift the burner completely
out of the unit to access the orifi ce.
e. Using a
3
/
8
" socket, remove orifi ce from the
orifi ce holder (see Fig. 5-3) and check the
number stamped on the orifi ce face.
number stamped on the orifi ce face.
f. If an orifi ce change is necessary, replace the
orifi ce with the correct sized one.
g. Replace the sideburner tube over the orifi ce,
aligning the burner over the electrode,
taking care not to detach it from the wire.
taking care not to detach it from the wire.
h. Replace the burner retaining clip (underneath
burner), burner top, cooking grid, and lid.
Important:
If converting the gas type, see the
CHECKING AND CONVERTING
THE REGULATOR section before
replacing the control panel.
CHECKING AND CONVERTING
THE REGULATOR section before
replacing the control panel.
i. Replace the control panel, being sure to
reconnect the battery holder assembly
wires. Replace the control knob.
wires. Replace the control knob.
2. CONNECTING THE GAS SUPPLY TO YOUR
FIRE MAGlC SINGLE SIDEBURNER
a. The burner manifold has a
1
/
2
" male fl are
fi tting gas inlet elbow. A
1
/
2
" female fl are
fi tting connector nut is required to hook the
gas supply to the burner.
gas supply to the burner.
b. Use a stainless steel fl ex connector to bring
the gas supply from the gas line stub or
propane gas tank to the single sideburner
manifold. A
propane gas tank to the single sideburner
manifold. A
1
/
2
" x 24" or 36" fl ex connector
is suitable for most installations.
CAUTION: Use only a C.S.A. listed stainless
steel fl ex connector. Do not use a
rubber hose or plastic hose within the
enclosure for your single sideburner;
it will leak, resulting in an explosion
and/or serious injury.
rubber hose or plastic hose within the
enclosure for your single sideburner;
it will leak, resulting in an explosion
and/or serious injury.
ORIFICE IS LOCATED
AT THE END OF THE
VALVE
Fig. 5-2
Fig. 5-1
Fig. 5-3
GAS SUPPLY PLUMBING REQUIREMENTS
Orifi ce is located at