GE JP201CBSS Utilisation Et Entretien

Page de 16
Consumer Support
Troubleshooting T
ips
Installation Instructions
Care and Cleaning
Operating Instructions
Safety Instructions
10
Installation of the cooktop.
Read these instructions completely and carefully.
Tools You Will Need
■ 1/8″ Drill bit
■ Electric or hand drill
■ Flat blade screwdriver
■ Pencil
■ Ruler or tape measure and straightedge
■ Hand saw or saber saw
Before You Begin
Read these instructions completely 
and carefully.
IMPORTANT—Save these instructions 
for local inspector’s use.
IMPORTANT—Observe all governing codes 
and ordinances.
NOTE TO INSTALLER—Be sure to leave these
instructions with the Consumer.
NOTE: This appliance must be properly
grounded. 
Electrical Requirements
CAUTION: for personal safety, remove house
fuse or circuit breaker before beginning
installation.
This appliance must be supplied with the proper
voltage and frequency and connected to an
individual, properly grounded branch circuit,
protected by a circuit breaker or time delay fuse,
as noted on the rating plate.
All wire connections must be made in accordance
with local codes and properly insulated. Check
with your local utility for governing electrical
codes and ordinances. 
In the absence of local electrical codes, the
National Electrical Code, ANSI/NFPA No.
70–Latest Edition, governing electric range
installations, must be followed. 
A copy of the National Electrical Code can be
obtained by writing to: 
National Fire Protection Association
Batterymarch Park
Quincy, MA 02260
If you fail to wire your counter unit in
accordance with governing codes, you 
may create a hazardous condition.
Electrical Connections
DANGER: The electrical power to the
counter unit supply line must be shut off while
line connections are being made. Failure 
to do so could result in serious injury or death.
You must use a two-wire A.C. 208/240 Volt, 
60 Hertz electrical system. A white (neutral) wire
is not needed for this unit. The white lead from
the household electrical supply can be isolated
and secured in the junction box. If you connect 
to aluminum wiring, properly installed connections
listed for use with aluminum and copper wiring 
must be used.
Use a minimum wire size of No. 12 copper wire
with a 20 Amp fuse or circuit breaker for both
208/240 Volt electrical systems. 
When making the wire connections, use the
entire length of conduit provided. The conduit
must not be cut.
Connect the red and black leads from the
counter unit conduit to the corresponding leads
in the junction box.
The bare ground wire in the conduit is connected
to the counter unit frame. It must be connected
to the household electrical supply ground.
Location of 
rating plate