Kenyon B4050 Manuel Du Propriétaire

Page de 10
 
 
3
 
 
All models of the Kenyon glass cook tops 
simply “drop-in” to the appropriate cut-out 
and are secured with hardware designed for 
each particular model. 
 
Mounting - Ceramic Glass Tops 
 
Your Kenyon ceramic glass cook top is 
supplied with two sheet metal mounting 
brackets. These brackets are designed to 
hold your cook top firmly in place. The cook 
top has a metal frame and should be sealed 
to the counter top using a non-hardening 
bedding compound that will permit later 
removal without damage should service be 
necessary. We recommend linseed oil 
based materials such as Pettit #7110 White 
Seam Compound. If silicone compounds 
are used, later removal may result in 
damage to the cook top. 
Attach the two mounting brackets, supplied 
with your Kenyon cook top, to the inside 
vertical surface of the cut-out. The brackets 
are to be mounted on opposing sides. 
Center the bracket in the opening, flush with 
the counter top and secure with the #6 x 1 
¼” screws, provided. 
 
Position the cook top in the cut-out opening 
and press firmly on all sides  
to seal the frame into the bedding 
compound. 
 
Secure the cook top to the brackets from 
underneath with the #8 x ¼” screws 
supplied. Be careful not to over-tighten the 
screws. 
 
Wiring 
 
All of the Kenyon glass cook tops are 
supplied with a three wire “pigtail” for 
connection to the boats AC power 
distribution system. These leads are tinned 
copper with high temperature insulation. 
 
It is recommended that the supply 
conductors be protected with a (double pole 
simultaneous trip for 240v applications) 
circuit breaker rated per the specifications 
for the various models and voltages as 
shown in the Electrical Requirements Table. 
110V AC Installations 
The black lead is the live or hot conductor, 
the white lead is the neutral conductor and 
the green lead is the ground wire. 
240V AC Installations 
The black and red leads are live or hot 
conductors, the green lead is the ground 
wire. 
 
Ventilation 
 
Adequate ventilation of the space below the 
countertop must be provided to ensure 
proper operation of the cook top. Heat 
transferred from the cook top bottom pan 
during operation will overheat an improperly 
ventilated area.  
 
A minimum of 6 square inches of cross 
ventilation is recommended. 
 
Other appliances, such as a refrigerator, 
installed within the enclosure must also be 
considered when providing ventilation. 
 
 
 
 
 
 
 
t^okfkd
t^okfkd
t^okfkd
t^okfkd=
=
=
=
Installation must comply with applicable standards of the ABYC and/or the  
“Fire Protection Standards For Motor Craft, NFPA #302”. 
Be sure to provide adequate ventilation.