Planning the Installation
 
WARNING
• 
IMPORTANT: Observe all governing codes and ordinances 
during planning and installation. Contact your local building 
department for further information.
•  To prevent an electric shock hazard, the power supply 
must meet the specifications stated below. It is the owner’s 
responsibility to make sure that the electrical service meets 
electrical requirements and that the electrical outlet has 
been properly installed by a licensed electrician.
The appliance installation must be electrically grounded in 
accordance with local codes or, in the absence of local codes, 
with the National Electrical Code, ANSI/ NFPA 70:
Electrical Requirements
• 
The range is supplied with a factory installed, 6 foot long, 
power cord with a three-prong grounding plug. It is connected 
to the chassis at the rear of the range. It must be connected 
to a dedicated, grounded three-prong electrical outlet.
• 
The correct voltage, frequency, and amperage must be 
supplied to the appliance from a separate, grounded, circuit 
that is protected by a properly sized circuit breaker or time- 
delay fuse.
Circuit Required
Total Connected Load*
120 Vac, 60 Hz, 15 Amp.
120 Vac 60 Hz, 5.0 Amp.
*These specifications for reference only. Refer to the rating label 
for exact specifications (see below for location).
Gas Supply Requirements
• 
The installation of this appliance must conform with local 
codes or, in the absence of local codes, with the National 
Fuel Gas Code, ANSI Z223.1/NFPA 54.
• 
Be certain that the appliance being installed is correct for 
the gas service provided (natural gas or LP gas). Also, if 
operating the range at an altitude above 4000 ft. (1219 m) 
make sure it is equipped for high altitude operation. Refer 
to the range rating label and the table on the inside cover to 
determine the correct model.
• 
See the table below for gas supply pressure requirements.
• 
The range comes from the factory with the regulator 
installed. Use only the installed regulator. The regulator inlet 
accommodates a 3/4” gas line. The range ships with a 1/2” to 
3/4” adapter connected to the regulator.
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Minimum  
Manifold Pressure
Minimum Gas 
Supply Pressure**
Natural Gas
5-inch Water 
Column
6-inch Water 
Column
Liquid Propane 
(LP)
10-inch Water 
Column
11-inch Water 
Column
* The gas supply pressure for testing the regulator setting shall 
be at least 1 inch water column (249 Pa) above the specified 
manifold pressure.
** Maximum gas supply pressure for all models: 1/2 psi.
The ratings above are for reference only. Refer to the rating label 
for exact specifications (see below left for location).
B
A
Power 
cord
Gas 
Inlet
GAS - ELECTRICAL ACCESS DIMENSIONS
A
B
13 1/16” to 14 3/8” 
(33.18 to 36.51 cm)
4 5/16”  
(10.95 cm)
Rating Label Location
Rating label is on top of 
kickplate.
Open door and look 
through gap to view label 
information.