12
Remove and discard 
10. 
the mounting plates 
attached to both blow-
er motors.
Remove the nuts that 
11. 
hold the rear mount-
ing plates in place 
and remove. See 
below.
Attach the mounting plates removed in step 11 (rear 
12. 
mounting plate) to the blower motors.
Insert the opening of each blower motor assembly into 
13. 
the holes inside the back of the hood. The connector 
on the motors must be toward the bottom of the hood. 
Attach them with four (4) nuts each.
Installation Instructions
Tip the hood back, so that it lays on its back with the 
4. 
front pointing up.
Remove the filters from the under side of the hood.
5. 
Locate the wiring harness. Cut the cable tie that takes 
6. 
up the slack in the cable. It is located behind the panel 
on the right side inside the hood. Also cut the two (2) 
cable ties that hold the wiring harness to the brace 
inside the hood, on the right side. See below.
Remove and save all the nuts that hold the wiring har-
7. 
ness cable clamps in place. Remove and save the 
clamps.
Disconnect both wiring harness connectors from the 
8. 
blower motors.
While supporting each blower from below, remove the 
9. 
four (4) nuts that hold the blower and mounting plates 
in place. Remove both blowers from the hood.
Remove cable 
clamps
Remove 
cable ties
Wiring Harness
Connector 
locations
Remove 
and discard
Rear Mounting 
Plate