Program Location 04 (PL04)
HI Temp cool down temperature/time
Location to be viewed/changed.
Press “Perm Press” key.
Display will read “HICd,” HI Temp
cool down status for 3-seconds and then
the actual temp and time programmed.
If no change press “Perm Press” key
twice, otherwise press “HI” or “LO”
key and then “Perm Press” key.
Summary: Cool down temperature is programmable from a minimum of 70° F to a maximum of 190° F in ten degree increments
or from a minimum of 21° C to a maximum of 88° C in five-degree increments.
Cool down is programmable from 0 to 9 minutes.
PL04
HICd
Perm Press
·
100
·
2
HI Temp
Perm Press
LO Temp
Refer to Programming
Instructions for instructions on
entering program locations.
(Wait 3-Seconds)
Continued
from PL03.
100
·
2
LO Temp
HI Temp
Perm Press
PL05
Proceed to next location
to be changed
To exit program mode,
open program switch
Temperature Decrease
Temperature Increase
Time Decrease
Time Increase