Movincool OFFICEPROW20 Guide D’Installation Rapide

Page de 2
          
      
QUICK START GUIDE
Of�ice Pro W20
                                                                                
      
 
 
 
• Moving the unit:
1
2
 
3
 
 
 
.
4
  
NEXT PAGE
Refer to the operation manual and pay attention to all the warnings and cautions throughout the manual
NOTE: Refer to the operation manual for details on choosing the installation site
A) Roll the unit into the space that needs cooling
Unlock the casters and push the MovinCool unit using the side handles to a flat, level
surface and set the casters back to the LOCKED position.
B) OPTION 1 set up steps
C) OPTION 2  set up steps
• Water Pipe Connection:
NEXT PAGE
Left Side Handle
Right Side Handle
      
Installation Options
(Based on the Condenser Inlet Water Connection)
OPTION 1     Water Pipe Connection: Pipes are field supplied.
                              Two water pipes with the 1/2 inch NPT male end connections are 
                       required.
OPTION 2     Garden Hose Connection:  Garden hoses are available as optional accessory. 
                              Part Number: 
GX484009-0920
1) Remove the caps from the female NPT connections on the right side panel of the 
    unit.
Note: Small residues of water may drip when the caps are first removed.
2) Apply teflon tape to the male threads on the two pipes.
3) Connect the two water pipes with the male end connections to the female 
    connections on the unit. 
 
WRENCH A
WRENCH B
4) Hold the wrench A tightly so that the pipe on the unit is not deformed, then 
     tighten the connector with the wrench B as shown in the figure below.
5) Make sure that water pipes are connected properly, and there is no 
    water leakage.
• 
Garden Hose Connection: 
2) Apply teflon tape to the male threads on the two supplied garden hose adapters.
3) Screw the supplied garden hose adapters to the female NPT connections on the 
     unit as shown in the figure below. 
4) Connect the optional water hoses to the garden hose adapters. Hold the hose-
    end connector with the wrench B tightly to prevent hose rotation. Then tighten 
    the swivel nut with the wrench A (see figure below).
WRENCH A
WRENCH B
5) Connect the other end of the garden hoses to the water source. Make sure that 
     the garden hoses are connected properly, and there is no water leakage. 
 
D) Power up the unit:
Note:
Plug the unit and turn it on. 
Voltage Requirement: 1 phase, 115V
Recommended Fuse Size:  15 amps
NEMA Plug Configuration: 5-15 
Office Pro W20 unit has two female 1/2 inch NPT (National Pipe Thread) water connections.
1) Remove the caps from the female NPT connections on the right side panel of the 
    unit.
Note: Small residues of water may drip when the caps are first removed.
Entering Water Temperature*: Between 40 °F  to 90 °F
Water Pressure: 150 psi (1,034 kPa) or less
*If the entering water temperature is below 68 °F (20 °C) or above 86 °F (30 °C), 
  adjustment of the unit's water regulating valve setting is required. Please refer 
  to the operation manual for details. 
WRENCH A
WRENCH B
4) Hold the female NPT connections on the unit with wrench A and then tighten 
     garden hose adapters with wrench B (see figure below).