To Replace the Filter:
1. To reinstall the filter, place the back edge of the filter into the 
channel at the rear of the range hood. 
2. Pull the filter latch toward the front of the range hood and 
push the front of the filter up into place. 
3. Release the filter latch. It will spring back into place to secure 
the filter.
4. Replace the screw in the filter retainer.
Replacing a Halogen Lamp
Turn off the range hood and allow the halogen lamp to cool. To 
avoid damage or decreasing the life of the new lamp, do not 
touch the lamp with bare fingers. Replace the lamp, using tissue 
or wearing cotton gloves to handle the lamp.
If new lights do not operate, make sure the lamps are inserted 
correctly before calling service.
1. Disconnect power.
2. Use a flat-blade screwdriver and gently pry the light cover 
loose.
3. Remove the lamp and replace it with a 120-volt, 40-watt 
maximum, halogen lamp made for a G-9 base.
4. Replace the light cover.
5. Reconnect power.
WIRING DIAGRAM
SE119A
Gnd
Ground
Screw
M
S15
Switch Operation
L-1
Lamps 120 V 1.5 Ohms
L-2
Speed 1 120 V 1.5 Ohms
L-3
Speed 2 120 V 2.0 Ohms
2.5 Ohms
120 V
Speed 3
L-4
0.9 ±10% A
110 Watts 
 
27.5 ±10% Ohms
 
55.7 ±10% Ohms
Motor Characteristics
Power Supply
120 VAC
Frequency
60 Hz
Amperage
Wattage Rating
Motor Resistance
Red - Brown
Red - Black
Red - Gray
86.8 ±10% Ohms
W (Common)
BK (Line)
BK (Line)
Y (Lamp)
GY (Speed 3)
R (Speed 2)
BR (Speed 1)
Mechanical push buttons
4 buttons       3 speeds
Y
Y
W
BR
8uF
Y
W
Common
R
Speed 3
Speed 2
Speed 1
BR
W
GY
BK
N
L
Red - White
117.7 ±10% Ohms