Hold the range hood firmly in place with one hand and bend each 
mounting tab (A) upward approximately 90°.
Mark the hole at the power supply knockout (B).
OPTIONAL: Mark the hole in each mounting tab.
For a non-vented (recirculating) installation: Go to Step 7.
For a top vented installation: Mark the 4 vent hole locations (C) 
on the top of the range hood.
For a rear vented installation: Mark the 4 vent hole locations (D) 
on the rear of the range hood.
Remove the range hood and set it aside.
6. Mark and Cut Vent Opening 
3
¹⁄₄" x 10" (8.3 x 25.4 cm) Rectangular Vent System
Using a 
¹⁄₂" (13 mm) drill bit, drill a hole in each of the dots 
marked previously on either the wall or upper cabinet. Using 
the outside edges of the holes, mark the vent opening.
Using a jigsaw or keyhole saw, cut the vent opening.
7" (17.8 cm) Round Vent System
Using the 7" (17.8 cm) round vent mounting plate, draw the 
vent opening outline on the underside of the cabinet:
-
Place the vent mounting plate on the bottom of the 
cabinet. Position the edge of the plate with the widest 
distance (A) between the hole and edge of the mounting 
plate against the wall. Position the side edges of the 
mounting plate between the dots marked previously.
IMPORTANT: The widest edge (A) of the vent mounting plate 
must be positioned against the wall.
-
Trace the 7" (17.8 cm) vent opening (solid line) on the 
cabinet bottom.
Using a jigsaw or keyhole saw, cut the vent opening 1" 
(2.5 cm) larger than the 7" (17.8 cm) hole traced (dashed line).
7. Drill Electrical Opening
Using a 1
¹⁄₄" (3 cm) drill bit, drill the hole in the dot marked 
previously at the electrical strain relief.
OPTIONAL: Using a 
¹⁄₈" (3 mm) drill bit, drill pilot holes for the 
dots marked previously at each mounting tab at an approximate 
45° angle in an upward direction.
D
D
A
90˚
C
C B
      1" 
(2.5 cm)