KitchenAid UXL6048YSS Utilisation Et Entretien

Page de 36
12
8. Connect the green (or yellow/green) ground wire to the 
green/yellow ground wire (H) in the terminal box using UL 
listed wire connectors.
9. Reinstall the in-line blower terminal box cover and screw.
10. Reinstall the front cover of the in-line blower housing and 
secure it with 10 mounting screws.
Electrical Connection Inside Hood Liner Between In-line 
Blower System and Hood Liner
1. With the hood liner mounted (see the “Install Hood Liner” 
section), locate the wiring cable connector inside the hood 
liner.
2. Connect the 6-wire connector assembly supplied with the 
in-line blower motor system to the mating cable connector 
from the hood liner. 
3. Locate the terminal box inside the hood liner and install a 
¹⁄₂" (1.3 cm) UL listed or CSA approved strain relief (see 
“Complete Preparation” in the “Prepare Location” section). 
4. Run the wire ends from the 6-wire connector assembly 
through the 
¹⁄₂" (1.3 cm) strain relief, leaving enough wire 
length to make the wiring connections. Tighten the strain 
relief screws.
5. Connect the wires from the 6-wire connector assembly to the 
wires from the wiring conduit inside the hood liner terminal 
box. 
6. Connect the same color wires to each other (black to black, 
white to white, etc.) using UL listed wire connectors.
NOTE: Connect the green (or green/yellow) ground wire from 
the wiring conduit to the green (or bare) ground wire from the 
home power supply using UL listed wire connectors (see the 
“Make Electrical Power Supply Connection to Hood Liner” 
section).
7. Go to the “Make Electrical Power Supply Connection to Hood 
Liner” section.
Make Electrical Power Supply Connection 
to Hood Liner
1. Disconnect power.
2. Locate terminal box inside of the hood liner.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire 
in terminal box.
Failure to do so can result in death or electrical shock.
A. UL listed or CSA approved 
¹⁄₂
" (1.3 cm) wiring conduit
B. UL listed wire connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or green/yellow) 
wire
I. 6-wire connector assembly
A. Terminal box cover
B. Terminal box
A
B
C
D
E
F
G
H
I
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B