CellarPro Wine Cellar Mini-Split Refrigeration System Manuel De Montage

Page de 1
 
 
38
 
 
 
* * I M P O R T A N T * *    
I N S T A L L E R S   M U S T   F I L L   O U T   T H I S   S H E E T   A N D  
F A X   T O  
7 0 7 . 7 9 4 . 8 0 0 5   O R   S C A N   /   E M A I L   T O   I N F O @ C E L L A R P R O . C O M
 
T O   A C T I V A T E   T H E   W A R R A N T Y .
 
Installing CellarPro Split Systems requires an experienced professional and adherence to industry practices which 
are described in the manual. To activate the warranty, the cooling unit must be installed properly. In order for us to 
assess and approve the installation, the installing technician must complete the page below. The page can be faxed 
to 707.794.8005 or emailed to info@cellarpro.com.  We will contact you once we receive and review this sheet. 
Technician Information 
  
 Name 
   
 
Phone 
 
System Information 
  
   
  
  
 
 
Piping Information
 
  
   
 
Customer Name 
 
R-134a system charge lb. 
 
  
Condensing Unit Model #  
 
Line-set length – ft. 
 
  
Condensing Unit Serial # 
 
Liquid line diameter – OD 
 
  
Evaporator Model #  
 
Suction line diameter
  - 
OD 
 
  
Evaporator Serial # 
 
 
 
 
 
Operational Data
 
 
Take the following measurements during a normal refrigeration cycle, once the cellar has pulled down to 
the set-point temperature.  Make sure the compressor is running when recording the data
.     
  
Evaporator 
Comment 
  
Air temperature at Evaporator coil inlet/outlet 
  
°F/°F 
8-10°F TD 
  
Evaporator fan speed (High / Med / Low) 
  
  
  
Evaporator power supply voltage & amps 
  
V & A 
103-127 V – check 
nameplate amps 
Condensing Unit 
  
Air temperature at Condenser coil inlet & outlet 
  
°F/°F 
20-30°F TD 
  
Condenser fan status (ON / OFF) 
  
  
  
Suction pressure at suction service valve 
  
PSIG 
25-35 PSIG 
  
Suction temperature at suction service valve 
  
°F 
20°F Superheat Min. 
  
Liquid pressure at liquid service valve 
  
PSIG 
105-180 PSIG 
  
Liquid temperature at liquid service valve 
  
°F 
10-20°F Subcooling 
  
Condensing Unit power supply voltage & amps  
  
V & A 
103-127 V – check 
nameplate amps