Summit Built-In Commercial Kegerator - Black Cabinet/Panel Ready Door Manuel D’Utilisation
2
7. The beer dispenser requires an AC power supply of 110~120V/60Hz and pulls a
current of over 10A. The fuse or circuit breaker should be rated at 15A.
8. If the leakage of a combustible gas is detected, turn off the gas valve and open the
doors and windows. To reduce the risk of fire caused by a spark, do not pull out the
plug of the beer dispenser or of any other electrical device.
plug of the beer dispenser or of any other electrical device.
SAFETY PRECAUTIONS REGARDING CO
2
(CARBON DIOXIDE) GAS
Always connect the CO
2
cylinder to a regulator! Failure to do so may cause an
explosion resulting in possible injury or death when the cylinder valve is opened.
Never connect the CO
Never connect the CO
2
cylinder directly to the product container.
Always keep CO
2
cylinders away from heat. Store extra cylinders in a cool place
(preferably below 70°F). Securely fasten cylinders with a chain in an upright position
when storing.
Never drop or throw a CO
when storing.
Never drop or throw a CO
2
cylinder.
Always check the D.O.T. (Department of Transportation) test date on the cylinder neck
before installation. If it has been more than 5 years, do not use. Return the cylinder to
your gas supplier.
Never connect a product container unless there are at least two safety devices in the
pressure system: one on the CO
before installation. If it has been more than 5 years, do not use. Return the cylinder to
your gas supplier.
Never connect a product container unless there are at least two safety devices in the
pressure system: one on the CO
2
regulator and the other on the product container or in
the pressurized gas line.
The recommended pressure for the CO
The recommended pressure for the CO
2
system is 8-10 lbs.
SAVE THESE INSTRUCTIONS
Notes on Energy Consumption
This product is designed for commercial use and is UL approved to standard 471
(commercial refrigeration). It features an upgraded cooling system over units
designed for household use. At national average electric rates it will use less
than $1 per month more in electricity than household units.
Tips to save energy and maintain optimum performance:
(commercial refrigeration). It features an upgraded cooling system over units
designed for household use. At national average electric rates it will use less
than $1 per month more in electricity than household units.
Tips to save energy and maintain optimum performance:
When positioning this unit: If used freestanding allow 4 inches of clearance on
top, at the sides and in the rear for sufficient airflow. If unit is built in, allow 2” of
air space between the rear of the unit and the wall; also leave at least 1/8” on
both sides and 1/16” at the top. Be sure that airflow under the appliance is not
blocked.
top, at the sides and in the rear for sufficient airflow. If unit is built in, allow 2” of
air space between the rear of the unit and the wall; also leave at least 1/8” on
both sides and 1/16” at the top. Be sure that airflow under the appliance is not
blocked.