USING YOUR ELECTRONIC CONTROL
ALARM RESET
Power Failure
•  Power failure - 
If power to the appliance is inter-
rupted the System Status indicator will turn-off and 
the "Power Failure" indicator will flash. Additionally, an 
"ALARM RESET" indicator will be displayed below the 
"On/Off" keypad. No audible tone will sound. This alarm 
condition can be reset by momentarily pressing the 
"On/Off" keypad. If this alarm occurs, it is recommend-
ed that you check the condition of any perishables, 
even if the appliance is operating normally and the tem-
perature has recovered, as prolonged power outages 
could result in excessive temperature excursions which 
may spoil perishables.
•  Temperature alarm - 
If the storage compartment 
temperature exceeds 10°F from set-point for more than 
a 1-hour duration, the System Status indicator will turn 
off, the "Temp" indicator will flash, and an audible tone 
will sound every 60-seconds. Additionally, an "ALARM 
RESET" indicator will be displayed below the "On/Off" 
keypad. This alarm condition can be reset by momen-
tarily pressing the "On/Off" keypad. If this alarm occurs 
it is recommended that you check the condition of your 
stored contents, even though the appliance is operating 
normally and the temperature has recovered, as pro-
longed temperature excursions could spoil perishables.
ALARM RESET
Temp
NOTE
Door Ajar
Temp
Multiple alarms are possible, i.e.- "Door Ajar" for a pro-
longed period may trigger a "Temp" alarm, in which case 
both "Door Ajar" and "Temp" indicators will activate.
Door Ajar
ALARM RESET
•  Door ajar - 
If the door is open, or not closed prop-
erly, for more than 5-minutes the System Status OK 
indicator will turn-off, the "Door Ajar" indicator will flash, 
and a tone will sound every 60 seconds. Additionally, 
an "ALARM RESET" indicator will be displayed below 
the "On/Off" keypad. This alarm condition can be reset 
by closing the door or momentarily pressing the "On/
Off" keypad, (i.e.-if you are cleaning the storage com-
partment, etc.). The alarm will recur in 5-minutes if the 
alarm condition persists.
Alarms:
The control will alert you to conditions that could adversely 
affect the performance of the appliance.