Electrolux EW30IS80RS Référence De Câblage
UI Display
Error Description
Corrective Action
11
Shorted keypad. The defective control
will flashes the error code in its display.
will flashes the error code in its display.
1- Cycle power on affected zone. If stuck button comes back while zone is on then proceed.
2- Verify there is no mechanical interference near the defective control (harness, metallic devices, etc.).
3- Replace defective control.
2- Verify there is no mechanical interference near the defective control (harness, metallic devices, etc.).
3- Replace defective control.
14
Touch panel tail missing
Disconnect power, wait 30 seconds and reapply power. If fault returns:
1- Verify harnesses between ESEC-UIB and the Touch Panel.
2- Replace ESEC-UIB.
3- Replace the Touch Panel.
1- Verify harnesses between ESEC-UIB and the Touch Panel.
2- Replace ESEC-UIB.
3- Replace the Touch Panel.
15/16/17
FMEA Error.
Replace defective control.
20
Loss of communication with ID1
Generator Housing Assembly.
Generator Housing Assembly.
1- Check communication harness attached to the ID1 Induction Generator Housing. Replace if defective.
2- Verify ID1 Connection is the proper one.
3- Replace ID1 generator.
2- Verify ID1 Connection is the proper one.
3- Replace ID1 generator.
21
Loss of communication with ID2
Generator Housing Assembly.
Generator Housing Assembly.
1- Check communication harness attached to the ID2 Induction Generator Housing. Replace if defective.
2- Verify ID2 Connection is the proper one.
3- Replace ID2 generator.
2- Verify ID2 Connection is the proper one.
3- Replace ID2 generator.
23
Loss of communication between 2 or
more generator.
more generator.
1- Check communication harness from UI to harnesses and generator to generator.
2- Check ID1 connection to verify that the ID jumper is connected from BC1 to BC5.
2- Check ID1 connection to verify that the ID jumper is connected from BC1 to BC5.
30/70/90
AC input voltage too high in either ID1,
ID2 place designated by UI display.
ID2 place designated by UI display.
1- Verify AC Input voltage at cooktop input (customer wiring) and AC from pole.
2- Verify AC voltage between BPL and PBN connectors should measure 240V AC +- 24V AC.
3- Replace Induction Generator Housing.
2- Verify AC voltage between BPL and PBN connectors should measure 240V AC +- 24V AC.
3- Replace Induction Generator Housing.
31/71/ 91
Internal generator error ID1/ ID2.
Replace Induction Generator Housing ID1, ID2.
32/72/92
Power supply defect ID1/ ID2.
Replace Induction Generator Housing ID1, ID2.
33/73/93
Cooling fan blocked ID1/ID2.
1- Verify there is no interference for the fan.
2- Replace generator housing ID1, ID2.
2- Replace generator housing ID1, ID2.
34/74/94
Main AC Phase error ID1/ID2
Replace generator housing ID1, ID2.
35/75/95
Main AC voltage too low ID1/ID2.
1- Check line voltage coming into the house if all zones are showing this error.
2- Replace generator housing ID1, ID2.
2- Replace generator housing ID1, ID2.
36/76/96
Internal communication error ID1/ID2.
Replace generator housing ID1, ID2.
37/77/97
Internal induction generator housing
error ID1, ID2.
error ID1, ID2.
Replace generator housing ID1, ID2.
38/78/98
Fan not connected ID1, ID2.
1- Verify fan is correctly connected at BS1.
2- Replace induction generator housing ID1, ID2.
2- Replace induction generator housing ID1, ID2.
39
Configuration mismatch between
generator and UI control.
generator and UI control.
1- Verify if user interface is the right one for that model.
2- Verify if generators are the correct type.
3- If all displays are showing this error replay UI otherwise replace appropriate generator.
2- Verify if generators are the correct type.
3- If all displays are showing this error replay UI otherwise replace appropriate generator.
40/80/A0
IGBT heat sink sensor error ID1/ID2.
1- Verify if the heat sink sensor is installed properly (measure approx. 100kOhm for NTC).
2- Replace generator housing assembly ID1, ID2.
2- Replace generator housing assembly ID1, ID2.
41/81/A1
Induction sensor (coils) defect ID1/ID2.
1- Verify if the inductor (coils) are connected properly (measure approx. 0Ohm at room temperature).
2- Replace the induction generator housing if 0 ohm otherwise the inductor (coil).
2- Replace the induction generator housing if 0 ohm otherwise the inductor (coil).
42/82/A2
General pot detection alarm ID1/ID2.
1- Verify pans are the proper type (magnet sticks to the bottom of pan).
2- Verify pan is not warped or rusty, pan is proper size, pan is placed correctly.
3- Replace induction generator housing ID1, ID2.
2- Verify pan is not warped or rusty, pan is proper size, pan is placed correctly.
3- Replace induction generator housing ID1, ID2.
43/83/A3
Pot detection sensor fail ID1/ID2.
1- Verify pan is not warped or rusty, pan is proper size for zone, pan is placed correctly.
2- Replace induction generator housing ID1, ID2.
2- Replace induction generator housing ID1, ID2.
44/84/A4
Board temperature warning ID1/ID2.
1- Ensure customer is not using the cooktop with a dry pan at a high temperature level.
2- Allow zone to cool down and then continue cooking.
2- Allow zone to cool down and then continue cooking.
45/85/A5
Board temperature alarm ID1/ID2.
1- Ensure customer is not using the cooktop with a dry pan at a high temperature level.
2- Replace induction generator housing ID1, ID2.
2- Replace induction generator housing ID1, ID2.
51/52/53
54/55/56
54/55/56
Element temperature sensor failure ID1/
ID2.
ID2.
1- Verify induction temperature sensor is connected properly at B71 or B81 as per wiring diagram.
2- Verify the inductor temperature sensor is installed properly and not damaged (measure approx. 100K
Ohms at room temperature).
3- Replace induction generator housing ID1, ID2.
2- Verify the inductor temperature sensor is installed properly and not damaged (measure approx. 100K
Ohms at room temperature).
3- Replace induction generator housing ID1, ID2.
63/64/65
66/67/68
66/67/68
Element temperature sensor too hot
ID1/ID2.
ID1/ID2.
1- Ensure customer does not use the cooktop with a dry pan at high temperature levels.
2- Verify the inductor temperature sensor is installed properly and not damaged in the proper generator
(measure approx. 100k Ohms at room temperature).
3- Replace induction generator housing ID1, ID2.
2- Verify the inductor temperature sensor is installed properly and not damaged in the proper generator
(measure approx. 100k Ohms at room temperature).
3- Replace induction generator housing ID1, ID2.
UI Display
Error Description
Corrective Action
71
Internal generator error. Sync, Induction
Housing Assembly / Right side cooking
zones.
Housing Assembly / Right side cooking
zones.
1- Check all cables and connectors on the Right Side Generator Circuit Board, replace if defective.
2- Replace the Right Side Generator Circuit Board.
2- Replace the Right Side Generator Circuit Board.
72/73
Power Supply defect. Induction Housing
Assembly / Right side cooking zones
Assembly / Right side cooking zones
1- Test all cables & connections on Filter Circuit Board.
2- Replace the Filter Circuit Board.
3- Replace the Right Side Generator Circuit Board.
2- Replace the Filter Circuit Board.
3- Replace the Right Side Generator Circuit Board.
74
Internal generator error.
Communication, Induction
Housing Assembly / Right side cooking
zones.
Communication, Induction
Housing Assembly / Right side cooking
zones.
1- Check cable between Filter Circuit Board, connector X13 and the Right Side Generator Circuit Board,
connector X10.
2- Replace the Filter Circuit Board.
3- Replace the Right Side Generator Circuit Board.
2- Replace the Filter Circuit Board.
3- Replace the Right Side Generator Circuit Board.
76
Communication error. Induction
Housing Assembly / Right side cooking
zones.
Housing Assembly / Right side cooking
zones.
1- Verify communication harness between ESEC-UIB P9 connector and Filter Circuit Board X20/X14,
replace if damaged.
2- Verify communication harness going between Filter Circuit Board, connector X13 and Right Side
Generator Circuit Board, X10 connector. Replace if defective.
3- Replace Filter Circuit Board.
4- Replace the Right Side Generator Circuit Board. 5- Replace ESEC-UIB.
replace if damaged.
2- Verify communication harness going between Filter Circuit Board, connector X13 and Right Side
Generator Circuit Board, X10 connector. Replace if defective.
3- Replace Filter Circuit Board.
4- Replace the Right Side Generator Circuit Board. 5- Replace ESEC-UIB.
77
Heat sink temperature sensor break,
Induction Housing Assembly / Right
side cooking zones.
Induction Housing Assembly / Right
side cooking zones.
Replace the Right Side Generator Circuit Board.
ADDITIONAL ERROR (FAULT) CONDITIONS
Symptom or failure
Control Display
Possible cause or condition
Suggested Corrective Action
Pan does not heat up.
Normal operation.
Pan too small for proper pan detec-
tion and only works with low power.
tion and only works with low power.
Use larger pan or this pan on a smaller cooking zone. Refer to
owners guide for proper pan selection.
owners guide for proper pan selection.
Flashing "Power level"
and pan does not heat.
and pan does not heat.
Pan not detected.
Check whether the pots or pans are suitable for induction. Refer to
owners guide for proper pan selection.
owners guide for proper pan selection.
Induction coil not correctly
connected or induction coil open.
connected or induction coil open.
Check the coil wire terminal connections. Ensure that they are
properly connected and tightened. Test continuity of coil (should be
less than 1 ohm).
properly connected and tightened. Test continuity of coil (should be
less than 1 ohm).
Distance between coil and glass
ceramic too large.
ceramic too large.
Check whether the coil is properly positioned and touching the glass
cooktop surface.
cooktop surface.
Individual buttons cannot be
used or cannot always be
used.
used or cannot always be
used.
None.
Test cables & connections. Touch
control defective.
control defective.
1. Follow instructions for proper use of touch controls. 2. Replace
Touch Control.
Touch Control.
Cooking power too low or
shuts down prematurely.
shuts down prematurely.
None.
Fluids spilled or object lying on
control panel keypads.
control panel keypads.
Clean up spills or remove objects. Restart cooktop in normal
manner.
manner.
Normal operation
Ventilation slots obstructed.
Clear vent openings.
Unsuitable pots ( bottom bent).
Follow owners guide for proper pan selection.
Distance between coil and glass
ceramic too large.
ceramic too large.
Check whether the glass ceramic was pushed down when being
screwed in position and the coil has been correctly positioned.
screwed in position and the coil has been correctly positioned.
HE in display when cooking
zone is cold and switched off.
zone is cold and switched off.
"HE"
Temperature sensor defect.
1. Test coil sensor , approximately 100Kohms at room
temperature. Replace coil if resistance is incorrect. 2. Replace
power generator board.
temperature. Replace coil if resistance is incorrect. 2. Replace
power generator board.
ERROR CODES