Q-Logic 59047-10 D Manuel D’Utilisation

Page de 264
4–Fibre Alliance MIB Objects
connUnitProduct (1.3.6.1.3.94.1.6.1.7)
59047-10  D
4-9
Refer to 
 for connectivity unit return values. Return value will be OK 
(3), uninstalled IO or CPU boards are ignored
connUnitProduct (1.3.6.1.3.94.1.6.1.7)
The sml attribute Config.Snmp.SysDescr. This is the system description shown on 
the 'show version' Telnet screen. It can also be read on the 'show setup snmp' 
screen and written using the 'set setup snmp' Telnet screen.
Syntax
DisplayString (SIZE (0..79))
Access
read-only
Status
mandatory
Return Value
Returns the switch SystemDescription: QLogic 5200 = SANbox 5200 FC 
Switch, QLogic 5202 = SANbox 5602 FC Switch, QLogic 5600 = SANbox 
5600 FC Switch, QLogic 5602 = SANbox 5602 FC Switch, QLogic 9100 = 
SANbox 9100 FC Switch, QLogic 9200 = SANbox 9200 FC Switch.
connUnitSn (1.3.6.1.3.94.1.6.1.8)
The serial number for this connectivity unit.
Syntax
DisplayString (SIZE (0..79))
Access
read-only
Status
mandatory
Return Value
The chassis serial number.
Table 4-4. QLogic 9000 Series Connectivity Unit Return Values
Status
Return Value
If either FAN or PS boards are not installed
warning (4)
If all FANs or all PS boards are not 
installed
failed (5)
If installed board's faultList is not NONE
warning (4)