Chapter  2 - Configuring HDSL Parameters
Campus-REX2 RS Interface Card User Manual
27
2
From the System Settings Menu, type 
then press 
. The System 
Parameters screen is displayed.
Setting HDSL Alarms
The default setting for all alarming is Disabled. Completing the following 
steps to either select a value or to enable the alarm reporting.
1
To select an HDSL ES Alarm Threshold (Disabled is the default), type 
then press 
 to select one of the following as the ES threshold:
17 errored seconds occurring in a 24-hour period
170 errored seconds occurring in a 24-hour period
An alarm is generated when the defined threshold for HDSL errored 
seconds is exceeded, indicating a deterioration in performance. An 
errored second is one in which one or more block errors (CRC 
anomalies) or LOSW defects occur within the threshold interval.
2
To configure the HDSL Margin Alarm Threshold:
a
Type then 
press 
.
b
At the prompt, enter a value between 1 and 25 decibels (dB) then 
press
.
Enter Margin alarm threshold value (1-25dB), or "D"
to disable>6
An alarm is generated when the defined threshold for HDSL Margin is 
exceeded. Margin indicates the signal to noise ratio at a receiver point.
1
ENTER
Jul 07, 2003 
ADC TELECOMMUNICATIONS, CAMPUS RS, Version 5.1 08:19:34
Local Unit ID:
Local I/F:
REX2
Remote Unit ID:
Remote I/F: REX2
Circuit ID:
SYSTEM PARAMETERS
1) CHANGE SYSTEM TIME
2) CHANGE SYSTEM DATE
3) CHANGE UNIT ID
4) CHANGE CIRCUIT ID
5) CHANGE UNIT PASSWORD
6) HDSL ES Alarm Threshold:
Disabled
(Disabled, 17, 170)
7) HDSL Margin Alarm Threshold:
Disabled
8) Local Data Port LOS Alarm:
Disabled
(Disabled, Enabled)
9) Remote Data Port LOS Alarm:
Disabled
(Disabled, Enabled)
10) RESTORE FACTORY DEFAULTS
(R)eturn
(M)ain Menu
ENTER CHOICE>
6
ENTER
7
ENTER
ENTER