ADC Campus-REX2 RS Manuel D’Utilisation

Page de 166
 
Chapter 3 - Configuring the REX2
Campus-REX2 RS Interface Card User Manual
31
Configuring Bridge Protocol, Encapsulation and Timing
The Campus-REX2, as a default configuration, bridges Ethernet frames.
1
Type 
then press 
 if bridge is not selected.
2
To change the packet encapsulation, type 
then press 
. Select an 
Encapsulation option:
cHDLC for Campus-REX2 to another Campus-REX2 application
PPP when the remote Campus unit has a synchronous interface card 
such as a V.35 or when connecting to Ethernet equipment from 
another manufacturer
3
To change the timing source, type 
 then press 
. Select a timing 
source setting:
Internal (default setting) which takes its timing from an internal 
oscillator
HDSL which takes its timing from the HDSL link
The Timing Source option determines the source of circuit timing on the 
HDSL link. The proper setting of the Timing Source option depends 
upon the interface card of the remote Campus unit:
If the Campus-REX2 is connected to a Campus unit with another 
Campus-REX2, leave the Timing Source option set to Internal. Set 
the other end (remote) of the connection to HDSL; the Campus 
system will not operate properly if both units are set to HDSL.
If the Campus-REX2 is connected to a Campus unit with a 
synchronous interface card, such as a Fractional V.35 card, the 
timing source depends on the setting of the Primary Timing Source 
option of the remote unit:
Set the Timing Source to HDSL if the remote unit is set to 
Internal or Data Port.
Set the Timing Source to Internal if the remote unit is set to 
HDSL.
See the Campus-RS Fractional Interface Card User Manual for 
information on the Primary Timing Source option.
If the Campus-REX2 is connected to a Campus unit with a Campus 
CSU/DS-1 or CSU/DSX-1 interface card, set the Timing Source 
option to Internal.
1
ENTER
2
ENTER
3
ENTER