ADC Campus-REX2 RS Manuel D’Utilisation

Page de 166
 
Chapter 5 - Monitoring and Testing the Campus System
Campus-REX2 RS Interface Card User Manual
87
Performing Loopback Testing
Loopbacks provide testing for the HDSL data communication path between 
the Campus unit, the remote unit, and the remote host equipment. Loopback 
tests can be run only when one end of the HDSL connection (either the local 
or the remote) is a Campus-REX2 or Campus-REX (both ends cannot be 
Campus-REX2 or Campus-REX).
The following section describes how to set up, run, and terminate 
loopback tests.
Configuring Loopbacks
The Campus-REX2 supports the following types of loopbacks between a 
Campus-REX2 and another Campus unit that contains a synchronous 
interface card such as V.35 or DSX-1:
The Remote to Remote loopback tests the remote data port.
The Local to Remote loopback tests the remote data port, the entire data 
path inside the remote Campus unit, the HDSL line, the HDSL 
transceivers of both units, and most of the internal data path inside the 
local unit. This loopback does not test the local data port drivers and 
receivers.
Once a loopback condition has been initiated, it remains in effect until it is 
cleared. You may also set a loopback timeout to clear the loopback 
automatically after a set period of time has elapsed.
If both the local and remote Campus units have a 
Campus-REX2 RS Interface Card, no loopbacks are 
supported between the two units.