Options for Enhanced Event Action
Options for Enhanced Event Action
Table 6-12:   
Action
Label
Display
ProLink II
ProLink III
Field Communicator
Standard
None (default)
NONE
None
None
None
Start sensor zero
START ZERO
Start Sensor Zero
Start Sensor Zero
Perform auto zero
Start/stop all totaliz-
ers
START STOP
Start/Stop All Totalization
Start/Stop All Totalization
Start/stop totals
Reset mass total
RESET MASS
Reset Mass Total
Reset Mass Total
Reset mass total
Reset volume total
RESET VOL
Reset Volume Total
Reset Volume Total
Reset volume total
Reset gas standard
volume total
RESET GSVT
Reset Gas Std Volume
Total
Reset Gas Std Volume
Total
Reset gas standard vol-
ume total
Reset all totals
RESET ALL
Reset All Totals
Reset All Totals
Reset totals
Petroleum measurement
Reset temperature-
corrected volume to-
tal
TCVOL
Reset API Ref Vol Total
Reset Volume Total at
Reference Temperature
Reset corrected volume
total
Concentration measurement
Reset CM reference
volume total
RESET STD V
Reset CM Ref Vol Total
Reset Volume Total at
Reference Temperature
Not available
Reset CM net mass to-
tal
RESET NET M
Reset CM Net Mass Total Reset Net Mass Total
Not available
Reset CM net volume
total
RESET NET V
Reset CM Net Vol Total
Reset Net Volume Total
Not available
Increment CM matrix
INCr CURVE
Increment Current CM
Curve
Increment Concentration
Matrix
Not available
Meter verification
Start meter verifica-
tion test
START VERFY
Start Meter Verification
Start Meter Verification
Not available
CAUTION!
Before assigning actions to an enhanced event or discrete input, check the status of the event
or the remote input device. If it is ON, all assigned actions will be performed when the new
configuration is implemented. If this is not acceptable, wait until an appropriate time to assign
actions to the event or discrete input.
Integrate the meter with the control system
Configuration and Use Manual 
123