Emerson MMI-20019043 Manuel D’Utilisation

Page de 374
4.3.1
Configure Volume Flow Type for gas applications
Display
Not available
ProLink II
ProLink
 > Configuration > Flow > Vol Flow Type
ProLink III
Device Tools
 > Configuration > Process Measurement > Flow
Field Communicator Configure > Manual Setup > Measurements > GSV > Volume Flow Type > Standard Gas Volume
Overview
Volume Flow Type
 controls whether liquid or gas standard volume flow measurement is
used.
Restriction
If you are using the petroleum measurement application, you must set Volume Flow Type to Liquid. Gas
standard volume measurement is incompatible with the petroleum measurement application.
Restriction
If you are using the concentration measurement application, you must set Volume Flow Type to Liquid.
Gas standard volume measurement is incompatible with the concentration measurement
application.
Procedure
Set Volume Flow Type to Gas Standard Volume.
4.3.2
Configure Standard Gas Density
Display
Not available
ProLink II
ProLink
 > Configuration > Flow > Std Gas Density
ProLink III
Device Tools
 > Configuration > Process Measurement > Flow
Field Communicator Configure > Manual Setup > Measurements > GSV > Gas Ref Density
Overview
The Standard Gas Density value is used to convert the measured flow data to the standard
reference values.
Prerequisites
Ensure that Density Measurement Unit is set to the measurement unit you want to use for
Standard Gas Density
.
Configure process measurement
Configuration and Use Manual 
35