OPERATING FIREPLACE
Continued
2.  The receiver continuously receives signals 
from the hand-held remote to control the 
room temperature. If the hand-held remote 
is misplaced, obstructed or for any reason 
cannot transmit to the receiver, the receiver 
will shut off the fireplace after 8 minutes.
Key Pad Lock Feature
This  feature  allows  the  user  to  lock/unlock 
the  keypad  on  the  hand-held  remote  in  the 
MANU or AUTO mode to prevent inadvertent 
operation (i.e. children operating the hand-held 
remote control, etc.). The keypad is locked in 
either on or off. Press the POWER and LOCK 
buttons together to turn the unit on or off.
 OPTIONAL BLOWER 
OPERATION
 WARNING: This fireplace has 
a three-prong, grounded electrical 
plug. This plug helps protect you 
against electrical shock. Only con-
nect plug to a properly grounded, 
three-prong receptacle. Do not cut 
or remove the grounding prong 
from this plug.
Locate  the  blower  switch  by  opening  lower 
louver on fireplace. Blower switch is located at 
lower left inside louver door. 
The GA3700TA thermostat-controlled blower 
has a variable speed control with an ON/OFF 
switch. The blower will start when the ther-
mostat senses a sufficient increase in firebox 
temperature.  The  GA3700  variable  speed 
blower also has an ON/OFF switch built into 
the variable speed control. 
Note  for  GA3700TA  Only:
 If you are using 
GA3700TA blower, your fireplace and blower 
will not turn on and off at the same time. The 
fireplace may run for several minutes before the 
blower turns on. After the heater modulates to 
the pilot position, the blower will continue to 
run. The blower will shut off after the firebox 
temperature decreases.
Note:
 It is safe to operate fireplace with blower 
turned off. However, the blower helps distribute 
heated air from the fireplace.
Follow installation instructions included with 
the blower accessory.
Figure 38 - Correct Pilot Flame Pattern
Pilot Burner
Figure 39 - Incorrect Pilot Flame Pattern
Pilot Burner
Thermocouple
MAIN BURNER
Periodically inspect all burner flame holes with 
the heater running. All slotted burner flame holes 
should be open with yellow flame present. All 
round burner flame holes should be open with a 
small blue flame present. Some burner flame holes 
may become blocked by debris or rust, with no 
flame present. If so, turn off heater and let cool. 
Remove blockage. Blocked burner flame holes 
may create soot.
INSPECTING BURNERS
Check pilot flame pattern and burner flame pat-
terns often.
PILOT FLAME PATTERN
Figure  38  shows  a  correct  pilot  flame  pattern. 
Figure 39 shows an incorrect pilot flame pattern. 
The incorrect pilot flame is not properly heating 
the thermocouple. When the thermocouple cools, 
the heater will shut down.
If pilot flame pattern is incorrect, as shown in 
Figure 39
•  turn heater off (see To Turn Off Gas to Appli-
ance
, page 20)
•  see Troubleshooting, page 25
Note:
 The pilot flame on natural gas units will 
have a slight curve, but flame should be blue and 
have no yellow or orange color.
Thermocouple