Nilfisk-Advance America SR 1100 P/B Manuel D’Utilisation

Page de 30
S31NUK5120(3)2001-04
MAINTENANCE
BATTERIES: CONTROL AND RECHARGE
Make a frequent check of the electrolyte level 
inside every battery cell. The battery 
compartment is under the operator seat; lift the 
lid and open the caps of all the battery cells: 
when necessary fill up the cells with distilled 
water. 
The proper electrolyte level is specified in the 
Manual for use and maintenance of the battery.
Warning: On the version with petrol engine the 
battery level check must be done every week.
After filling close all the cell caps and clean the 
top of the battery from any acid remains.
Warning: the battery acid is corrosive; if it comes 
in contact with the skin or eyes rinse thoroughly 
with water and consult a physician.
When necessary proceed with a recharge of the 
battery according to the following instructions 
and taking also into account what is specified in 
the Battery User Manual:
- switch the machine Off and remove the master 
key.
Warning: before starting the recharge the 
battery connector must be disconnected 
from the machine.
- the recharge must be done in a well ventilated 
area
- open all the cell caps
- connect the battery connector to the battery 
charger connector
- connect the battery charger cable to the mains 
(please check that the voltage and frequency of 
the mains correspond to the data of the 
charger)
At the end of the recharge disconnect the battery 
from the charger and fit the battery connector to 
the machine. Close all the cell caps and clean 
the top of the battery from any acid remains.
Note: in any case refer to the instructions 
specified in the Battery Use Manual.
19