Nilfisk-Advance America SR 1100 P/B Manuel D’Utilisation

Page de 30
S31NUK5120(3)2001-04
The machine is equipped with many safety 
devices and functions which have been 
described in the USE paragraphs (both for petrol 
and electrical versions). For instance the 
automatic stop of all functions to avoid the deep 
discharge of the battery has been mentioned; 
and also the availability of a special red key for 
the disengagement of the self-breaking function 
has been notified: this is to be operated when the 
machine must be pushed in Off condition.
Besides the intervention of other safety functions 
is notified by means of dedicated safety codes 
appearing on the display. These safety codes 
are described in the following table.
SAFETY FUNCTIONS AND TROUBLE-
SHOOTING
26
TO PUSH
TO DRIVE
SEE SAFETY CODE 333
SAFETY 
CODE
MACHINE BEHAVIOUR
DESCRIPTION OF THE 
MALFUNCTION
POSSIBLE INTERVENTION
205
Stop of all functions except 
traction
The battery is empty
Recharge the battery according to 
the instructions given in the 
Maintenance paragraph
301
Stop of all functions and traction
Overtemperature of the drive motor
-If the machine run on a long ramp it 
could be normal: let the machine 
cooling 20 minutes
-Check the efficiency of the front 
and rear brakes
-Check the rotation of the rear drive 
wheels
302
The machine does not start or, in 
the event it was working, will stop
Possible problem with traction 
control electronic circuit
-Check carbon brushes of traction 
motor
-Check connection cables of 
traction motor
-If the above is OK replace the 
power electronic board
305
The machine functions will stop
High temperature on the electronic 
control circuits (95 °C)
-If the ambient temperature is high 
let the machine cool down 20 
minutes 
-If the problem will remain call the 
technical service to check the 
electrical motors
306
Stop of all functions and traction
High temperature on the electronic 
control circuits (105 °C)
-Make the same checks as per code 
305
307
The machine does not start
Wrong start sequence
-Release the accelerator pedal 
before turning the key On
308
The machine does not start
Damage of the cable of 
potentiometer for traction control
-Check the cable connections of the 
potentiometer for traction control
- Check the potentiometer for 
traction control
333
The machine does not start
-Off status of the red key for the 
disabling of the self braking 
function (see the picture on the 
top page)
-Possible trouble of motor kables 
(short circuit or open circuit)
-Insert the red key and turn it 
clockwise
-Check the motor cables
800
Display flashing
Main brush worn
-Replace the main brush
E10
Flashing display
Main broom is blocked
Remove the main broom and clean 
all dirty parts