FILTER CLEANING AND REPLACEMENT
The panel filter requires a regular cleaning.
Lift the lid.
Remove the lid of the filter compartment.
Disconnect the electric cable of the filter-shaker 
motor (the machine must first be switched off 
and the key out).
Loosen the two screws with butterfly head on the 
two sides of the metal frame fixing the panel 
filter; it is not necessary to remove the screws 
completely.
Remove the metal frame and take the panel filter 
out.
Clean the filter shaking, blowing it with 
compressed air - pressure not higher than 6 bar- 
from the side where the metal protection net is 
mounted, to avoid damaging to the paper.
17